43
Basic Operations Using the Console
Section 4-3
These parameters can be displayed and changed if necessary
from Reading Settings (Manual). page 73
To turn the teaching function OFF, select Reading Settings
(Manual) from the screen shown in step 5, and press the ENT
Key. The teaching function will be turned OFF by entering the
Reading Settings (Manual) window.
10. This completes the settings.
4-3-3
STEP 3: Starting Code Reading
Enter RUN mode to perform readings. The reading judgment is out-
put to external devices through RS-232C.
Procedure
1,2,3...
1.
Confirm that the RUN indicator (orange) is lit.
2.
Press the Trigger Switch on the Scanner to read the code.
OK 6568ms
Freeze (3)
ABCDE12345
GrayEdgeVal: 18 (11~26), Rev: OFF
The parameters obtained are displayed. These
parameters are used as settings.
Only the read data (ABCDE12345 in this example)
is output to RS-232C.
Scn 0
RUN