40
Basic Operations Using the Console
Section 4-3
matically. If reading is not successful, the teaching function will re-
main ON; press the Trigger Switch again.
The parameters can be displayed and changed if necessary from
Reading Settings (Manual). page 58.
To turn the teaching function OFF, select Reading Settings
(Manual) from the screen shown in step 5, and press the ENT
Key. The teaching function will be turned OFF by entering the
Reading Settings (Manual) window.
Note If reading is not completed successfully, return to step (5.),
select Reading Settings (Manual), and press the ENT Key
to cancel the through image. Press the Shift+Up/Down
Keys and select a saved image from memory. Measure the
length of the finder pattern (L-shape) using Image Analy-
sis/Measure Length, return again to Reading Settings
(Manual), set the length of the finder pattern, and then per-
form teaching again. page 89
10. This completes the settings.
Trigger Switch
OK 1693ms
Freeze (13)
1234567890
Color: B, Rev: OFF, Length: 299
The obtained parameters are displayed. These
parameters are registered as reading conditions.
Scn 0
RUN
Only the read data (1234567890 in this example)
is output to RS-232C.