136
Error Codes
Section 6-3
Contents of System Data Commands
Note
1.
Expressed in 3 digits, e.g., 1 is expressed as 001.
2.
Expressed in 5 digits, e.g., 1000.0 is expressed as 10000 and 2.0
is expressed as 00020.
3.
There are 18 digits total for (1) to (12).
Output example: 410000000005050001
Area
Item
Num-
ber
Settings
RS-232C
Baud rate
(1)
0: 2,400 bps
1: 4,800 bps
2: 9,600 bps
3: 19,200 bps
4: 38,400 bps
Data length
(2)
0: 7 bits
1: 8 bits
Parity
(3)
0: None
1: Even
2: Odd
Stop bits
(4)
0: 1 bit
1: 2 bits
Header
(5)
0: None
1: STX
2: ESC
Footer
(6)
0: CR
1: LF
2: CR+LF
FCS
(7)
0: OFF
1: ON
Error output
(8)
0: OFF
1: ON
Flow control
(9)
0: None
1: RS/CS
2: Xon/Xoff
Timeout
(10)
1 to 120 s (See note 1.)
Buzzer setting
(11)
1.0 to 1,000.0 ms (See note 2.)
Image storage method
(12)
0: None
1: Only NG
2: All