126
Error Codes
Section 6-3
Error Codes for Pattern Data Matrix
• Items in dotted lines can be included or omitted by selecting
them on RS-232C setting menus. page 107.
• Any empty box indicates that one space is required.
Read Start Level Trigger: @GL
A read is performed. If reading is successful, reading is ended and
the reading judgement is output.
Send
Error code
Meaning
E160
Timing pattern detection error 1: No
finder patterns were detected for
models 1 or 2.
E161
Timing pattern detection error 2: 32
or more finder patterns were
detected for models 1 or 2.
E170
Finder pattern detection error 1: No
finder pattern was detected for
model ABC.
E171
Finder pattern detection error 2: 32
or more finder patterns were
detected for model ABC.
E172
Finder pattern detection error 3:
Relative positioning is incorrect for
model ABC.
E180
Decode error
E181
E182
E200
Timeout error
<Footer>
<FCS>
<Reading data>
<Header>
@
S
N
Insert one space.
<Footer>
<Scene No.>
@
G
L
<Footer>