107
System Mode
Section 5-3
5-3
System Mode
5-3-1
RS-232C Communications
Sets communications methods when communicating to external
devices via terminal RS-232C.
1,2,3...
1.
Select 2400, 4800, 9600, 19200, or 38400 (bps).
(Default setting: 38400)
2.
Select 7 or 8 (bits). (Default setting: 8)
3.
Select None, Odd, or Even. (Default setting: None)
4.
Select 1 or 2 (bits). (Default setting:1)
5.
Select None, STX, or ESC. (Default setting: None)
6.
Select CR, LF, or CR+LF. (Default setting: CR)
7.
Select OFF or ON. (Default setting: OFF)
8.
Select OFF or ON. (Default setting: OFF)
9.
None:
No flow control is performed (default).
RS/CS:
Hardware flow control is performed. Prepare a cable
to connect the RS and CS signals from the V530-
C300E to the external device. Data will be sent when
the CS signal from the external device is ON.
Xon/Xoff: Software flow control is performed. Data is sent
according to the Xon/Xoff codes sent from the exter-
nal device.
10. Set the time to generate a timeout error in seconds (Setting
range: 1 to 120 s; default setting: 5 s)
Baud rate
:
38400bps
▼
Data length
:
8bit
▼
Parity bits
:
None
▼
Stop bits
:
1bit
▼
Header
:
None
▼
Footer
: CR
▼
FCS
: OFF
▼
Error Output
:
OFF
▼
Flow control
:
None
▼
End
A
H
B
C
D
E
F
G
I
Timeout
: [ 5]s