background image

 
 
 
 
 
 

90-MILLIMETER COMPATIBLE 

SWIPE READER 

TECHNICAL REFERENCE MANUAL 

 
 
 

Part Number 99831083-5 

 
 
 
 

JULY 2003 

 
 
 
 
 

 

  

 

REGISTERED TO ISO 9001:2000 

20725 South Annalee  Avenue 

Carson, CA 90746 

Phone:  (310) 631-8602 

FAX:  (310) 631-3956 

Technical Support: (651) 415-6800 

www.magtek.com 

 

Summary of Contents for 99831083-5

Page 1: ...SWIPE READER TECHNICAL REFERENCE MANUAL Part Number 99831083 5 JULY 2003 REGISTERED TO ISO 9001 2000 20725 South Annalee Avenue Carson CA 90746 Phone 310 631 8602 FAX 310 631 3956 Technical Support 65...

Page 2: ...Specifications Clarified Connector information Added correct drawings Clarified Card Present Signal 3 25 Jul 01 Front Matter Added to Agency page FCC Class B UL and CUL CE Class B Added Copyright 2001...

Page 3: ...subject to abnormal working conditions This warranty does not apply when the malfunction results from the use of the Product in conjunction with ancillary or peripheral equipment where it is determin...

Page 4: ...wing two conditions 1 This device may not cause harmful interference And 2 This device must accept any interference received including interference that may cause undesired operation CANADIAN DOC STAT...

Page 5: ...ON 3 MOUNTING 3 CONNECTORS 4 TIMING 5 DATA 6 STROBE 6 CARD PRESENT 6 FIGURES Figure 1 1 90 millimeter Compatible Swipe Reader vi Figure 2 1 Reader Mounting Dimensions 3 Figure 2 2 Timing 5 TABLES Tabl...

Page 6: ...vi Figure 1 1 90 millimeter Compatible Swipe Reader...

Page 7: ...ctro Static Discharge IEC 1000 4 3 Radiated EMC Field 2X requirement IEC 1000 4 4 Electrical Fast Transient Burst requirement transmission on I O cable Flammability Meets UL94V 0 Recording Method Two...

Page 8: ...90 millimeter Compatible Swipe Reader REFERENCE DOCUMENT I O Interface for TTL Swipe Readers Technical Reference Manual P N 99875148 2...

Page 9: ...ECTION 2 INSTALLATION This section consists of installation and checkout of the Reader MOUNTING The dimensions for mounting without the cover are shown in Figure 2 1 Figure 2 1 Reader Mounting Dimensi...

Page 10: ...in 2 Black GND 22 01 2051 3 Orange DATA 0 100 inch Contact Spacing 4 Brown STROBE Mates to Molex 22 05 2051 5 Green CARD PRESENT Note Vcc 2 7 to 5 5 VDC Table 2 2 I O Connector for Dual Track 7 Pin Pi...

Page 11: ...0 mm Contact Spacing 8 White CARD PRESENT Mates to Molex 53014 0910 9 Black GND Note Vcc 2 7 to 5 5 VDC TIMING CARD PRESENT DATA STROBE Notes 1 Time out of the CARD PRESENT signal occurs approximately...

Page 12: ...t Data be loaded by the user with the leading edge negative of the Strobe CARD PRESENT Card Present will go low after 14 15 flux reversals from the head Card Present will return high 150 milliseconds...