![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838094.webp)
4-3
4-1 Monitor Mode
4
Functions
Output Voltage Monitor [d013]
Displays the output voltage value (Vac) of the Inverter.
The monitor LED indicator "V" lights up.
(Display)
0. to 600.: Displays in increments of 1 V.
Total RUN Time [d016]
Displays the Inverter RUN time.
(Display)
0. to 9999.
: Displays in increments of 1 hour.
1000 to 9999 : Displays in increments of 10 hours.
100 to
999
: Displays in increments of 1000 hours.
Power ON Time Monitor [d017]
Displays the total power ON time of the Inverter.
(Display)
0. to 9999.
: Displays in increments of 1 hour.
1000 to 999
: Displays in increments of 10 hours.
100 to
999
: Displays in increments of 1000 hours.
Fault Frequency Monitor [d080]
• Displays the number of times the Inverter has tripped.
(Display)
0. to 9999.
: Displays in increments of 1 time.
1000 to 6553 : Displays in increments of 10 times.
Fault Monitors 1 [d081], 2 [d082], 3 [d083]
•Displays the details of the last three trips.
The most recent trip is displayed on trip monitor 1.
(Display)
• Factor (E01 to E35)
*1
• Output frequency at the time of tripping (Hz)
• Output current at the time of tripping (A)
• Internal DC voltage at the time of tripping (V)
• Total RUN time before the trip (hr)
• Total power supply time before the trip (hr)
*1. Refer to "Error Code List" (page 5-1) or "Trip Monitor Display" (page 5-4).
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......