![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838151.webp)
4-60
4-2 Function Mode
4
Func
tions
Multi-function Output Terminal ON Delay/OFF Delay
This function allows you to set ON/OFF delay times respectively from 0.1 to 100 seconds at the
signal output of the multi-function output terminals (P1 and relay). The following figure shows the
output status.
Multi-function Output Contact Selection
• You can set NO- or NC-contact output individually for multi-function output terminals P1 to P2 as
well as the relay output terminal.
• Multi-function output terminals P1 to P2 provide open-collector output. The relay output terminal
provides SPDT contact relay output.
Parameter No.
Function name
Data
Default setting
Unit
C144
Output terminal P1
ON delay
0.0 to 100.0
0.0
s
C145
Output terminal P1
OFF delay
0.0 to 100.0
0.0
s
C146
Output terminal P2
ON delay
0.0 to 100.0
0.0
s
C147
Output terminal P2
OFF delay
0.0 to 100.0
0.0
s
C148
Relay output
ON delay
0.0 to 100.0
0.0
s
C149
Relay output
OFF delay
0.0 to 100.0
0.0
s
Original signal waveform
(without delay)
ON delay only
OFF delay only
ON delay and
OFF delay
ON delay
ON delay
OFF delay
OFF delay
Parameter No.
Function name
Data
Default setting
Unit
C031 to C032
Multi-function output terminals
P1, P2 contact selection
00: NO contact
01: NC contact
00
C036
Relay output (MA, MB) contact
selection
00: NO contact between MA and MC
01: NC contact between MA and MC
01
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......