2-15
2-3 Wiring
2
Design
Wiring the Main Circuit Terminals
Connecting the Main Circuit Terminals
• For the main circuit terminals, always use insulated electrical wires with a rated voltage of 600 V and a rated
temperature of 80
°
C or higher.
• Use the crimp-type terminal with an insulating sleeve to connect to the terminals.
• Up to two wires can be connected to one terminal.
• To prevent possible voltage drops, increase the wire size in accordance with the cable length.
• To connect the 100-V or 200-V model to the relay output terminal, use a wire of 0.75 mm
2
.
• To connect seven wires or more to the control circuit terminal block, use a shield wire of 0.5 mm
2
or less.
• Strip the signal line by 5 to 6 mm, and connect the exposed wire. (In the case of stranded wires, make sure that
the wires are not unraveled.)
• Make sure that the maximum outside coating diameter of the signal line is 2.0 mm or less (except for the alarm
signal line). (For the mark tube mounted cable and multi-core cable, keep both the mark tube and the sheath-
stripped length 40 mm or more from the connecting end. A thick line may prevent proper closing of the cover
of the terminal block.)
• To meet the UL standards, always insert a UL-standard fuse (J type) on the power supply side.
• Use a ground wire with a larger diameter than that of the power cable shown above.
Motor output
(kW)
Applicable Inverter model
Wiring Applicable
device
Power cable
Earth leakage breaker
(ELB)
Fuse size
(class J)
Rated 600 V
0.2
3G3MX-A2002
1.25 mm
2
(5 A)
10 A
0.4
3G3MX-A2004
1.25 mm
2
(5 A)
10 A
3G3MX-A4004
3 A
0.75
3G3MX-A2007
2.0 mm
2
(10 A)
15 A
3G3MX-A4007
1.25 mm
2
(5 A)
6 A
1.5
3G3MX-A2015
2.0 mm
2
(15 A)
15 A
3G3MX-A4015
2.0 mm
2
(10 A)
10 A
2.2
3G3MX-A2022
2.0 mm
2
(20 A)
20 A
3G3MX-A4022
2.0 mm
2
(10 A)
10 A
3.7
3G3MX-A2037
3.5 mm
2
(30 A)
30 A
3G3MX-A4037
2.0 mm
2
(15 A)
15 A
5.5
3G3MX-A2055
5.5 mm
2
(50 A)
40 A
3G3MX-A4055
2.0 mm
2
(30 A)
20 A
7.5
3G3MX-A2075
8.0 mm
2
(60 A)
50 A
3G3MX-A4075
3.5 mm
2
(30 A)
25 A
0.2
3G3MX-AE002
1.25 mm
2
(5 A)
0.4
3G3MX-AE004
1.25 mm
2
(5 A)
0.75
3G3MX-AE007
2.0 mm
2
(10 A)
1.5
3G3MX-AE015
2.0 mm
2
(15 A)
2.2
3G3MX-AE022
2.0 mm
2
(20 A)
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......