4-40
4-2 Function Mode
4
Func
tions
RDY (Ready) Function
This function prepares for Inverter output to rotate the motor immediately after a RUN command is
input.
• When this function is enabled, the RUN (during RUN) LED indicator is always lit, since the Inverter
is in output status even though the motor stops.
• Allocate '52 (operation ready)' to any of multi-function inputs C001 to C006, or set b151 to '01'.
Refer to the table below for the correlation when the multi-function input '52' and b151 are set
simultaneously.
• When this function is enabled, data other than the parameters changeable during operation cannot
be changed.
<Group C: Multi-function Terminal Function>
The 3G3MX has six multi-function inputs [S1], [S2], [S3], [S4], [S5] and [S6]; two open collector out-
put terminals [P1], [P2]; two relay output terminals [MA] and [MB] (SPDT contact); and one analog
output terminal [AM].
Multi-function Input Selection
• You can allocate the following functions to any of multi-function inputs S1 to S6 (C001 to C006,
C201 to C206) to operate the set function.
• You can select NO- or NC-contact input for each multi-function input S1 to S6.
Parameter No.
Function name
Data
Default setting
Unit
b151
Ready function selection
00: Disabled
01: Enabled
00
Multi-function input terminal "52"
OFF
ON
b151 setting
00
OFF
ON
01
ON
ON
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......