![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838200.webp)
7-3
7-1 Standard Specification List
7
Specifications
*1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current
does not exceed that of the Inverter.
*2. Output voltage decreases according to the level of the power supply voltage.
*3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest
deceleration (when it stops from 50 Hz), not a continuous regeneration torque. Also, the average deceleration
torque varies depending on the motor loss. The value is reduced in operation at over 50 Hz. Note that no
braking resistor is built into the Inverter. If you need a larger regenerative torque, use an optionally available
braking resistor.
*4. Protection method complies with JEM 1030.
In
put si
gnal
Digital
Operator
signal
Frequency
settings
Setting with the FREQ adjuster and the Increment/Decrement keys on the Digital Operator,
variable resistance from 1 to 2 k
Ω
(2 W), 0 to 10 V DC (input impedance 10 k
Ω
),
4 to 20 mA (input impedance 250
Ω
), communication through an RS-485 port (Modbus
communication).
Forward/
Reverse
Run/Stop
Forward/Stop via the RUN/STOP keys (command selection for Forward or Reverse),
Reverse/Stop available at the time of terminal allocation (selectable from 1NO or 1NC),
Run/Stop through external communication.
Multi-function input
FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), RS (reset input),
AT (current input selection), USP (USP function), EXT (external trip),
OPE (forced OPE mode), STA (3-wire startup), STP (3-wire stop),
F/R (3-wire forward/reverse), FRS (free run stop), JG (jogging),
2CH (2-step acceleration/deceleration), DB (external DC injection braking),
SET (2nd control function), UP (UP/DWN function accelerated),
DWN (UP/DWN function decelerated), PID (PID enabled/disabled),
PIDC (PID deviation clear), PTC (thermistor input),
UDC (UP/DWN function data clear), SFT (soft lock),
ADD (frequency addition), F-TM (forced terminal block),
RDY (operation ready), SP-SET (special setting)
Ou
tp
ut
sig
nal
Multi-function output
RUN (signal during operation), FA1 (frequency arrival signal),
FA2 (over set frequency arrival signal), OL (overload warning signal),
OD (PID excess deviation signal), AL (alarm output),
ODC (communication option disconnected), FBV (PID FB status output),
NDc (Network error), LOG (Logic operation output)
Frequency monitor
Analog meter (0 to 10 V DC, 1 mA max.),
Frequency/Current signals are selectable via the analog output terminal.
Relay output
The relay (SPDT contact) outputs signals corresponding to the multi-function output.
O
the
r fu
nc
tion
s
AVR function, V/f characteristic selection, line acceleration/deceleration, upper/lower limit, 16-step speeds,
starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump,
analog gain/bias adjustment, S-shape acceleration/deceleration, electronic thermal level adjustment, retry
function, automatic torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd
control function, motor rotation speed UP/DWN, fan ON/OFF function
Ge
neral
sp
ecification
s
Ambient temperature
-10
°
C
to 40
°
C
(Carrier frequency: 5 kHz max.)
-10
°
C
to 50
°
C
(Both the carrier frequency and output current need to be reduced)
*7
Ambient storage temperature
-20
°
C
to 65
°
C
(short-time temperature during transport)
Humidity
20% to 90% RH
Vibration
5.9 m/s
2
(0.6G), 10 to 55 Hz
(Complies with the test method specified in JIS C0040 (1999).)
Location
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Applicable standard
Complies with UL, cUL, CE standards. (Insulation distance)
Options
Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.
Item
Specifications
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...