4-69
4-2 Function Mode
4
Functions
<Abnormal Response>
• If an error (aside from a communication error) is found in the query content, the Inverter returns an
exception response without performing any operation.
• To determine the cause of an error, check the function code of the response. The function code of
the exception response is the value of the query function code with 80h added.
•Check the details of the error with the exception code.
<No Response>
The Inverter ignores a query and does not respond if:
• The broadcast is received.
• A communication error is detected in receiving a query.
•The query slave address does not correspond with the slave address set for the Inverter.
• The time interval between 2 pieces of data constituting the message is less than a 3.5-character
length.
• Query data length is inappropriate.
Note: Provide a timer in the master to monitor the response, and if no response is returned within
the set time period, send the same query again.
Explanation of Each Function Code
<Reading Coil Status [01h]>
Reads out the coil status (ON/OFF).
(Example)
Read multi-function inputs S1 to S6 on the Inverter with slave address 8.
Refer to the following table for the multi-function input terminal statuses.
Field Configuration
Slave address
Function code
Exception code
CRC-16
Code
Description
01h
Has specified an unsupported function.
02h
Specified address does not exist.
03h
Specified data has an unacceptable format.
21h
Data is out of the Inverter's range for writing into the holding register.
22h
The Inverter does not allow this function.
• Has attempted to change the register that cannot be changed during operation.
• Has issued the enter command during operation (UV).
• Has written into the register during trip (UV).
• Has written into the read-only register (coil).
Multi-function
input terminals
S1
S2
S3
S4
S5
S6
Coils 13 and 14 are OFF.
Coil No.
7
8
9
10
11
12
Terminal status
ON
ON
ON
OFF
ON
OFF
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......