![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838039.webp)
2-14
2-3 Wiring
2
Design
Note 3: Separate the wiring from the power cable of the main circuit and from the wiring on the relay
control circuit. (More than 10 cm apart.)
Selecting the Sequence Input Method (Sink/Source Logic)
Ground connection is
not required.
Connect to the ground terminal of the Inverter.
Perform insulating
treatment.
Inverter's internal circuitry
When interface power supply is used
When external power supply is used
Si
nk l
ogic
Sou
rce
l
ogic
\
Inverter
PLC etc.
24 V DC
COM
PSC
S1
S6
SC
Inverter
PLC etc.
24 V DC
COM
PSC
S1
S6
SC
24 V DC
24 V DC
COM
P24
S1
S6
PSC
SC
Inverter
PLC etc.
PLC etc.
24 V DC
COM
PSC
P24
S1
S6
PSC
24 V DC
SC
Inverter
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......