![background image](http://html1.mh-extra.com/html/omron/sysdrive-3g3mx-a2002/sysdrive-3g3mx-a2002_user-manual_742838132.webp)
4-41
4-2 Function Mode
4
Functions
• The same two functions cannot be allocated to the multi-function inputs. If you attempt to allocate
the same two functions to the terminals by mistake, the terminal where you allocated the function
last takes precedence. The previous data is set to "255", and the terminal function is disabled.
* To switch to the 2nd control, allocate 08 (SET) to the multi-function input and then turn it on.
• Function codes C001/C201 to C006/C206 correspond to multi-function inputs S1 to S6
respectively.
• '19: Thermistor input' can be allocated only to multi-function input S6.
Parameter No.
Function name
Data
Default setting
Unit
C001
Multi-function input 1
selection
00: FW(forward)
01: RV(reverse)
02: CF1 (multi-step speed binary 1)
03: CF2 (multi-step speed binary 2)
04: CF3 (multi-step speed binary 3)
05: CF4 (multi-step speed binary 4)
06: JG (jogging)
07: DB (external DC injection braking)
08: SET (2nd control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (free run)
12: EXT (external trip)
13: USP (USP function)
15: SFT (soft lock)
16: AT (analog input switching)
18: RS (reset)
19: PTC (thermistor input)
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID enabled/disabled)
24: PIDC (PID integral reset)
27: UP (UP/DWN function accelerated)
28: DWN (UP/DWN function decelerated)
29: UDC (UP/DWN function data clear)
31: OPE (forced operator)
50: ADD (frequency addition)
51: F-TM (forced terminal block)
52: RDY (ready function)
53: SP-SET (special 2nd function)
255: No function
00
C201
*2nd multi-function
input 1 selection
C002
Multi-function input 2
selection
01
C202
*2nd multi-function
input 2 selection
C003
Multi-function input 3
selection
18
C203
*2nd multi-function
input 3 selection
C004
Multi-function input 4
selection
12
C204
*2nd multi-function
input 4 selection
C005
Multi-function input 5
selection
02
C205
*2nd multi-function
input 5 selection
C006
Multi-function input 6
selection
03
C206
*2nd multi-function
input 6 selection
C011
Multi-function input 1
operation selection
00: NO
01: NC
• NO contact: "ON" with the contact closed, "OFF"
with the contact open.
• NC contact: "ON" with the contact open. "OFF"
with the contact closed.
• For the RS terminal, only NO contact is available.
00
C012
Multi-function input 2
operation selection
00
C013
Multi-function input 3
operation selection
00
C014
Multi-function input 4
operation selection
00
C015
Multi-function input 5
operation selection
00
C016
Multi-function input 6
operation selection
00
Summary of Contents for SYSDRIVE 3G3MX-A2002
Page 1: ...Cat No I559 E1 01 USER S MANUAL SYSDRIVE MXSERIES Multi function Compact Inverter...
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 3...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Removing and Mounting Each Part 2 5 2 3 Wiring 2 10...
Page 90: ......
Page 91: ...Chapter 4 Functions 4 1 Monitor Mode 4 1 4 2 Function Mode 4 5...
Page 180: ......
Page 181: ...Chapter 5 Maintenance Operations 5 1 Special Display List 5 1 5 2 Troubleshooting 5 5...
Page 188: ......
Page 189: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 6 2 Storage 6 7...
Page 212: ...7 15 7 5 Options 7 Specifications 3G3AX RBU41 95 75 2 5 208 218 5 145 35 100 5...
Page 230: ......
Page 231: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 17...
Page 249: ...INDEX...
Page 252: ......