5-7
Section
NT620S/620C Status Control
236
touch switches, etc.
When bit 14 is turned OFF (0), this registration is canceled and the normal re-
sponse speed is reinstated. If priority registration is set for more than one PT,
the one for which the registration was made last will have priority.
By monitoring C200HX/HG/HE words, the unit number of the PT for which
priority registration has been set can be confirmed. For details on the monitor-
ing operation at the PC side, refer to the manual for the PC used.
[Connection to RS-232C port of C200HX/HG/HE]
Channel
Bit
Function
CIO265CH (standard
port)
CIO
CH (
A) (*)
0
Unit No.0 Communication in progress flag, ON
when connected
ort)
CIO284CH (port A) (*)
CIO285CH (port B) (*)
1
Unit No.1 Communication in progress flag, ON
when connected
2
Unit No.2 Communication in progress flag, ON
when connected
3
Unit No.3 Communication in progress flag, ON
when connected
4
Unit No.4 Communication in progress flag, ON
when connected
5
Unit No.5 Communication in progress flag, ON
when connected
6
Unit No.6 Communication in progress flag, ON
when connected
7
Unit No.7 Communication in progress flag, ON
when connected
8
Unit No.0 Priority registration lamp, ON when
registered
9
Unit No.1 Priority registration lamp, ON when
registered
10
Unit No.2 Priority registration lamp, ON when
registered
11
Unit No.3 Priority registration lamp, ON when
registered
12
Unit No.4 Priority registration lamp, ON when
registered
13
Unit No.5 Priority registration lamp, ON when
registered
14
Unit No.6 Priority registration lamp, ON when
registered
15
Unit No.7 Priority registration lamp, ON when
registered
(*)
This is the port of the communication board.
S
Continuous buzzer (bit 13), short intermittent buzzer (bit 12) and long intermit-
tent buzzer (bit 9)
The “continuous buzzer” sounds continuously without interruption.
The “short intermittent buzzer” sounds for 0.5 seconds at 0.5 second intervals.
The “long intermittent buzzer” sounds for 1.0 seconds at 1.0 second intervals.
If “1” (ON) is specified for more than one of the three buzzers at the same time,
the buzzers will sound in accordance with the following order of priority:
1.
Continuous buzzer
2.
Intermittent buzzer (short)
3.
Intermittent buzzer (long)