83
Backing Up Data
Section 4-3
When loading has been completed, the screen in (1.) will return.
4-3-2
Backing Up to Memory Cards
This section describes inserting a Memory Card and backing up settings data
to the Memory Card.
CHECK
Data can be backed up to Memory Cards inserted for screen group data.
Data for scene groups 1 to 31 will be saved in the files listed below. Do not
overwrite these files.
Precaution
Turn OFF the power supply to the Memory Card before removing the Memory
Card. Refer to page 99.
Saving from the F160 to the Memory Card
1.
Insert the Memory Card.
2.
Display the Basic Screen for Monitor Mode or Run Mode.
3.
Move the cursor to MON (or RUN) and press the ENT Key.
The mode selections will be displayed.
4.
Select TOOL.
Directory for saving scene group data
Scene group 1 file
Scene group 2 file
Scene group 31 file
[DEFSCNGR]
SGR_0001.SGR
SGR_0002.SGR
SGR_0031.SGR
Freeze
---- ---ms
0.Scn 0
MON
STEP/TRG:Msr S+
↑
↓
:Mem img
S+ENT:Help S+
→
:Adjust
S+ESC:Set disp
---- ---ms
0.Scn 0
MON
SET
MON
RUN
SYS
TOOL
SAVE
Summary of Contents for F160 Vision Sensor
Page 1: ...Cat No Z145 E1 02 F160 Vision Sensor Manual 2 CONVERSATIONAL MENU OPERATION MANUAL...
Page 2: ...F160 Vision Sensor Manual 2 Conversational Menu Operation Manual Revised June 2002...
Page 3: ...iv...
Page 5: ......
Page 9: ......
Page 55: ......
Page 131: ......
Page 137: ......
Page 139: ...130 Appendix B OK Dimns n NG E E OK Chip Bur NG F F OK Defect NG G G...
Page 143: ......
Page 145: ......
Page 148: ...Cat No Z145 E1 02 F160 Vision Sensor Manual 2 CONVERSATIONAL MENU OPERATION MANUAL...