61
Dimension
Section 3-4
A screen giving the option to specify the inspection end position will be dis-
played.
6.
Specify the end position (2nd position) that will measure the dimensions
using the same procedure.
The screen for changing the range for OK items will be displayed.
SeeAlso
Refer to page 19 for details on inputting values.
7.
Move the cursor to the value to be changed and set the range for OK items.
8.
Select End.
A confirmation message will be displayed.
9.
Select End if there are no more conditions to be added to the inspection.
0.Scn 0 =SET= Region
S+ESC:Adjust coordinates
↑
↓←→
: Move ENT:Set ESC: Back
0.Dimens'n
Specify the 2nd
position.
X= 227.962
Y= 81.541
Dist= 242.107
Dimensions and distance
Width X
Width Y
Distance
0.Scn 0 =SET= Region
End
Back
X : [ 225.000: 229.000]
Y : [ 79.000: 83.000]
Dist : [ 240.000: 244.000]
0.Dimens'n
Set the rangend
for OK items.
Range for OK items automatically calculated
by the F160 based on the coordinates.
X= 239.881
Y= 157.342
Dist= 286.821
End
Add
Add to inspection?
step
4
Summary of Contents for F160 Vision Sensor
Page 1: ...Cat No Z145 E1 02 F160 Vision Sensor Manual 2 CONVERSATIONAL MENU OPERATION MANUAL...
Page 2: ...F160 Vision Sensor Manual 2 Conversational Menu Operation Manual Revised June 2002...
Page 3: ...iv...
Page 5: ......
Page 9: ......
Page 55: ......
Page 131: ......
Page 137: ......
Page 139: ...130 Appendix B OK Dimns n NG E E OK Chip Bur NG F F OK Defect NG G G...
Page 143: ......
Page 145: ......
Page 148: ...Cat No Z145 E1 02 F160 Vision Sensor Manual 2 CONVERSATIONAL MENU OPERATION MANUAL...