PLC Comparison Charts
Appendix A
Data Move-
ment
Instruction
MOVE
MOV
Yes
Yes
Yes
Yes
Yes
DOUBLE MOVE
MOVL
Yes
Yes
No
Yes
No
MOVE NOT
MVN
Yes
Yes
Yes
Yes
Yes
DOUBLE MOVE
MVNL
Yes
Yes
No
Yes
No
DATA EXCHANGE
XCHG
Yes
Yes
Yes
Yes
Yes
DOUBLE DATA
EXCHANGE
XCGL
Yes
Yes
No
Yes
No
MOVE QUICK
MOVQ
No
No
No
Yes
No
BLOCK TRANS-
FER
XFER
Yes (Number
of words to be
transferred
specified in
binary: 0 to
65535.)
Yes (Number
of words to be
transferred
specified in
binary: 0 to
65535.)
Yes (Number
of words to be
transferred
specified in
BCD: 0 to 6144.)
Yes (Number
of words to be
transferred
specified in
BCD: 0 to 9999.)
Yes (Number
of words to be
transferred
specified in
BCD: 0 to 9999.)
BLOCK SET
BSET
Yes
Yes
Yes
Yes
Yes
MOVE BIT
MOVB
Yes (Source bit
position and
destination bit
position speci-
fied in binary.)
Yes (Source bit
position and
destination bit
position speci-
fied in binary.)
Yes (Source bit
position and
destination bit
position speci-
fied in BCD.)
Yes (Source bit
position and
destination bit
position speci-
fied in BCD.)
Yes (Source bit
position and
destination bit
position speci-
fied in BCD.)
MULTIPLE BIT
TRANSFER
XFRB
Yes
Yes
Yes
Yes (*1)
Yes
MOVE DIGIT
MOVD
Yes
Yes
Yes
Yes
Yes
SINGLE WORD
DISTRIBUTE
DIST
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
binary: 0 to
65535.)
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
binary: 0 to
65535.)
Yes (Stack oper-
ation function is
possible. Offset
value specified
in BCD: 0 to
8999.)
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
BCD: 0 to 9999.)
Yes (Stack oper-
ation function is
possible. Offset
value specified
in BCD: 0 to
8999.)
DATA COLLECT
COLL
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
binary: 0 to
65535.)
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
binary: 0 to
65535.)
Yes (Stack oper-
ation function is
possible. Offset
value specified
in BCD: 0 to
7999.)
Yes (Stack oper-
ation function is
possible with
another instruc-
tion. Offset value
specified in
BCD: 0 to 9999.)
Yes (Stack oper-
ation function is
possible. Offset
value specified
in BCD: 0 to
7999.)
EM BLOCK
TRANSFER
BETWEEN BANKS
BXFR
No (Functionally
possible for up
to 65,535 words
by directly
addressing EM
area using
XFER)
No (Functionally
possible for up
to 65,535 words
by directly
addressing EM
area using
XFER)
No
Yes (*1)
No
EM BLOCK
TRANSFER
XFR2
No
No
Yes
No
No
EM BANK TRANS-
FER
BXF2
No
No
Yes
No
No
MOVE TO REGIS-
TER
MOVR
Yes (No address
is specified for
indirect DM/EM.)
Yes (No address
is specified for
indirect DM/EM.)
No
Yes (Address is
specified for
indirect EM/DM.)
No
MOVE TIMER/
COUNTER PV TO
REGISTER
MOVR
W
Yes
Yes
No
No (Possible for
Completion
Flags only using
MOVR)
No
Item
Mne-
monic
CJ Series
CS Series
C200HX/HG/HE
CVM1/CV
Series
CQM1H
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...