335
PLC Comparison Charts
Appendix A
I/O Memory
CIO Area
Yes
Yes
Yes
Yes
Yes
WR Area
Yes
Yes
No
No
No
Temporary Relay
Area
Yes
Yes
Yes
Yes
Yes
Auxiliary Area
Yes
Yes
Yes
Yes
Yes
SR Area
No
No
Yes
No
Yes
Link Area
Yes (Data Link Area)
Yes (Data Link
Area)
Yes (Data Link
Area)
No
Yes
C200H Special I/O
Unit Area
Yes
Yes
Yes (CIO Area)
No
No
Built-in I/O Area
Yes (CJ1M CPU Unit
with built-in I/O only)
No
No
No
No
Serial PLC Link Area
Yes (CJ1M CPU Unit
only)
No
No
No
No
DM Area
Yes
Yes
Yes
Yes
Yes
Extended Data Mem-
ory (EM) Area
Yes (Addresses
including bank No.
can be designated)
(Not supported by
CJ1M CPU Unit)
Yes (Addresses
including bank
No. can be desig-
nated)
Yes (Addresses
can be desig-
nated for -Z, but
banks cannot)
Yes (Address
including bank
cannot be des-
ignated; bank
must be
changed. EM
Unit required.)
Yes (no banks)
Timer/Counter Area
Yes
Yes
Yes
Yes
Yes
Index Registers
Yes
Yes
No
Yes
No
Data Registers
Yes
Yes
No
Yes
No
Force-
set/
reset
areas
CIO Area
Yes
Yes
Yes
Yes
None
WR Area
Yes
Yes
No
No
Yes
Holding
Area
Yes
Yes
Yes
No
No
Auxiliary
Area
No
No
Yes
No
Yes
SR Area
No
No
No
No
No
Link Area
No
No
Yes
No
No
Timer/
Counters
Yes (Flag)
Yes (Flag)
Yes (Flag)
Yes (Flag)
Yes (Flag)
DM Area
No
No
No
No
No
EM Area
No
No
No
No
No
Instruction varia-
tions/ indirect
addresses
Upward differentia-
tion (executed once)
Yes (Specified by @)
Yes (Specified by
@)
Yes (Specified
by @)
Yes (Specified
by
↑
)
Yes (Specified
by @)
Downward differenti-
ation (executed once)
Yes (Specified by %)
Yes (Specified by
%)
No (DIFD
instruction used
instead)
Yes
(Specified by
↓
)
No (achieved
by using DIFD)
Immediate refresh
Yes (Specified by !)
Yes (Specified by
!)
No (IORF
instruction used
instead)
Yes
(Specified by !)
No (achieved
by using IORF)
Indi-
rect
ad-
dress-
ing for
DM/
EM
BCD mode
Yes (0000 to 9999)
Asterisk is used.
Yes (0000 to
9999)
Asterisk is used.
Yes (0 to 9999)
Yes (0 to 9999) Yes (0000 to
9999)
Asterisk is
used.
Binary mode Yes (00000 to 32767)
@ is used.
0000 to 7FFF Hex:
0000 to 31767
8000 to FFFF Hex:
00000 to 32767 in
next bank
Yes (00000 to
32767)
@ is used.
0000 to 7FFF
Hex: 0000 to
31767
8000 to FFFF
Hex: 00000 to
32767 in next
bank
No
Yes, but only
for indirect
addressing
using PLC
memory
addresses.
No
Item
CJ Series
CS Series
C200HX/HG/
HE
CVM1/CV
Series
CQM1H
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...