342
PLC Comparison Charts
Appendix A
Table Data
Processing
Instructions
SET STACK
SSET
Yes (Four words
of stack control
information.
Number of
words specified
in binary: 5 to
65535)
Yes (Four words
of stack control
information.
Number of
words specified
in binary: 5 to
65535)
No
Yes (Four words
of stack control
information.
Number of
words specified
in BCD: 3 to
9999)
No
PUSH ONTO
STACK:
PUSH
Yes
Yes
No
Yes
No
FIRST IN FIRST
OUT
FIFO
Yes
Yes
No
Yes
No
LAST IN FIRST
OUT
LIFO
Yes
Yes
No
Yes
No
FIND MAXIMUM/
FIND MINIMUM
MAX,
MIN
Yes (Two words
in control data
field. Table
length specified
in binary: 1 to
FFFF)
Yes (Two words
in control data
field. Table
length specified
in binary: 1 to
FFFF)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
Yes (One word
in control data
field. Table
length specified
in BCD: 1 to
999)
DATA SEARCH
SRCH
Yes (Table
length specified
in binary: 1 to
FFFF. PLC
memory address
output to IR0.
Number of
matches can be
output to DR0)
Yes (Table
length specified
in binary: 1 to
FFFF. PLC
memory address
output to IR0.
Number of
matches can be
output to DR0)
Yes (Table
length specified
in BCD: 1 to
6556. PLC
memory address
output to C+1.
Number of
matches cannot
be output to
DR0)
Yes (Table
length specified
in BCD: 1 to
9999. PLC
memory address
output to IR0.
Number of
matches cannot
be output to
DR0)
Yes (Table
length specified
in BCD: 1 to
6556. PLC
memory address
output to C+1.
Number of
matches cannot
be output to
DR0)
FRAME CHECK-
SUM
FCS
Yes
Yes
Yes
No
Yes
SUM
SUM
Yes (Same as
C200HX/HG/
HE: Sum possi-
ble for bytes as
well as words.)
Yes (Same as
C200HX/HG/
HE: Sum possi-
ble for bytes as
well as words.)
Yes (Sum possi-
ble for bytes as
well as words.)
Yes (Sum possi-
ble for words
only.)
Yes (Sum possi-
ble for bytes as
well as words.)
SWAP BYTES
SWAP
Yes (Can be
used for data
communications
and other appli-
cations.)
Yes (Can be
used for data
communications
and other appli-
cations.)
No
No
No
DIMENSION
RECORD TABLE:
DIM
Yes
Yes
No
No
No
SET RECORD
LOCATION
SETR
Yes
Yes
No
No
No
GET RECORD
LOCATION
GETR
Yes
Yes
No
No
No
Data Con-
trol Instruc-
tions
SCALING
SCL
Yes
Yes
Yes
No
Yes
SCALING 2
SCL2
Yes
Yes
No
No
Yes
SCALING 3
SCL3
Yes
Yes
No
No
Yes
PID CONTROL
PID
Yes (Output can
be switched
between 0% and
50% when PV =
SV. PID and
sampling period
specified in
binary.)
Yes (Output can
be switched
between 0% and
50% when PV =
SV. PID and
sampling period
specified in
binary.)
Yes (PID and
sampling period
specified in
BCD)
Yes (PID and
sampling period
specified in
BCD) (*1)
Yes (PID and
sampling period
specified in
BCD)
PID CONTROL
WITH AUTO-
TUNIG
PIDAT
CJ1: No
CJ1-H: Yes
CJ1M: Yes
CS1: No
CS1-H: Yes
No
No
No
LIMIT CONTROL
LMT
Yes
Yes
No
Yes (*1)
No
DEAD BAND CON-
TROL
BAND
Yes
Yes
No
Yes (*1)
No
DEAD ZONE CON-
TROL
ZONE
Yes
Yes
No
Yes (*1)
No
AVERAGE
AVG
Yes (Number of
scans specified
in binary)
Yes (Number of
scans specified
in binary)
Yes (Number of
scans specified
in BCD)
No
Yes (Number of
scans specified
in BCD)
Item
Mne-
monic
CJ Series
CS Series
C200HX/HG/HE
CVM1/CV
Series
CQM1H
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...