332
PLC Comparison Charts
Appendix A
Initial
set-
tings
(contd.)
Power
supply
Restart Continuation
Bit Hold
No
No
No
Set in PLC
Setup
No
Startup mode
Set in PLC Setup
Set in PLC Setup
Set in PLC
Setup
Set in PLC
Setup
Set in PLC
Setup
Startup Condition
Settings
CJ1: No
CJ1-H: Yes
CJ1M: Yes
CS1: No
CS1-H: Yes
No
No
No
Startup trace
No
No
No
Set in PLC
Setup
No
Detect low battery
voltage
Set in PLC Setup
Set in PLC Setup
Set in PLC
Setup
Set in PLC
Setup
Set in PLC
Setup
Momentary power
interruption time
No
No
No
Set in PLC
Setup
No
Power OFF detec-
tion delay time
Set in PLC Setup
Set in PLC Setup
Set in PLC
Setup
(Time that oper-
ation will con-
tinue after
power OFF has
been detected)
No
No
Momentary power
interruption as fatal/
non-fatal error
No
No
No
Set in PLC
Setup
No
Cycles
I/O refresh
No
No
Set in PLC
Setup (Special
I/O Units only)
Set in PLC
Setup
No
Constant cycle time
Set in PLC Setup(1 to
32,000 ms)
Set in PLC
Setup(1 to
32,000 ms)
Set in PLC
Setup(1 to
9,999 ms)
Set in PLC
Setup (1 to
32,000 ms)
Set in PLC
Setup(1 to
9,999 ms)
Monitor cycle time
Set in PLC Setup (10
to 40,000 ms) (Initial
setting: 1,000 ms
fixed)
Set in PLC Setup
(10 to 40,000 ms)
(Initial setting:
1,000 ms fixed)
Set in PLC
Setup (0 to 99)
Unit: 1 s
,
10 ms
,
100 ms (Initial
setting: 120 ms
fixed)
Set in PLC
Setup (10 to
40,000 ms)
(Initial setting:
1,000 ms fixed)
Set in PLC
Setup (0 to 99)
Unit: 1 s
,
10
ms
,
100 ms
(Initial setting:
120 ms fixed)
Detect cycle time
over disable
No
No
Set in PLC
Setup
No
Set in PLC
Setup
Asynchronous
instruction execution
and peripheral ser-
vicing
No
No
No
Set in PLC
Setup
No
Serial
com-
muni-
cations
RS-232C port com-
munications settings
DIP switch setting for
auto-detect or PLC
Setup
DIP switch set-
ting for auto-
detect or PLC
Setup
DIP switch set-
ting for defaults
or PLC Setup
DIP switch set-
ting for defaults
or PLC Setup
DIP switch set-
ting for defaults
or PLC Setup
Peripheral port com-
munications settings
Set in PLC Setup
Set in PLC Setup
PLC Setup
Set on DIP
switch.
Set in PLC
Setup
Communications
Board communica-
tions settings
No
No
PLC Setup
No
PLC Setup
CPU
pro-
cess-
ing
mode
Parallel processing
modes
CJ1: No
CJ1-H: Yes
CJ1M: No
CS1: No
CS1-H: Yes
No
No
No
Peripheral Servicing
Priority Mode
Yes
Yes
No
No
No
Servic-
ing
other
periph-
erals
Service time
Set in PLC Setup
(Fixed Peripheral Ser-
vicing Time)
Set in PLC Setup
(Fixed Peripheral
Servicing Time)
Set in PLC
Setup
(Built-in RS-
232C port,
Communica-
tions Board,
peripheral port)
No
Set in PLC
Setup
(Built-in RS-
232C port,
Communica-
tions Board,
peripheral port)
Measure CPU Bus
Unit service interval
No
No
No
Set in PLC
Setup
No
Stop Special I/O Unit
Cyclic Refreshing
Set in PLC Setup
Set in PLC Setup
Set in PLC
Setup
No
No
CPU Bus link appli-
cation
No
No
No
Set in PLC
Setup
No
Item
CJ Series
CS Series
C200HX/HG/
HE
CVM1/CV
Series
CQM1H
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...