![Omron CJ1G-CPU series Programming Manual Download Page 366](http://html1.mh-extra.com/html/omron/cj1g-cpu-series/cj1g-cpu-series_programming-manual_742489366.webp)
345
PLC Comparison Charts
Appendix A
Serial Com-
munica-
tions
Instructions
RECEIVE
RXD
Yes (Number of
stored bytes
specified in
binary) (Only
used for RS-
232C port in
CPU Unit. Can-
not be used for
Serial Communi-
cations Unit, or
CPU Unit’s
peripheral port)
Yes (Number of
stored bytes
specified in
binary) (Only
used for RS-
232C port in
CPU Unit. Can-
not be used for
Inner Board,
Serial Communi-
cations Unit, or
CPU Unit’s
peripheral port)
Yes (Number of
stored bytes
specified in
BCD) (Used for
peripheral port,
RS-232C port or
Communica-
tions Board in
CPU Unit.)
No
Yes (Number of
stored bytes
specified in
BCD) (Used for
peripheral port,
RS-232C port or
Communica-
tions Board in
CPU Unit.)
TRANSMIT
TXD
Yes (Number of
stored bytes
specified in
binary) (Only
used for RS-
232C port in
CPU Unit. Can-
not be used for
Serial Communi-
cations Unit or
CPU Unit’s
peripheral port)
(Unsolicited
communications
not possible
using Host Link
EX command)
Yes (Number of
stored bytes
specified in
binary) (Only
used for RS-
232C port in
CPU Unit. Can-
not be used for
Inner Board,
Serial Communi-
cations Unit, or
CPU Unit’s
peripheral port)
(Unsolicited
communications
not possible
using Host Link
EX command)
Yes (Number of
stored bytes
specified in
BCD) (Used for
peripheral port,
RS-232C port or
Communica-
tions Board in
CPU Unit.)
(Unsolicited
communica-
tions possible
using Host Link
EX command)
No
Yes (Number of
stored bytes
specified in
BCD) (Used for
peripheral port,
RS-232C port or
Communica-
tions Board in
CPU Unit.)
(Unsolicited
communica-
tions possible
using Host Link
EX command)
CHANGE SERIAL
PORT SETUP
STUP
Yes (10 words
set)
Can be used for
Serial Communi-
cations Unit.
Yes (10 words
set)
Can be used for
Serial Communi-
cations Unit.
Yes (5 words
set)
No
Yes (5 words
set)
PROTOCOL
MACRO
PMCR
Yes (Sequence
number speci-
fied in binary.
Four operands.
Can specify des-
tination unit
address and
Serial Port num-
ber.)
Yes (Sequence
number speci-
fied in binary.
Four operands.
Can specify des-
tination unit
address and
Serial Port num-
ber.)
Yes (Sequence
number speci-
fied in BCD.
Three oper-
ands.)
No
Yes (Sequence
number speci-
fied in BCD.
Three oper-
ands.)
PCMCIA CARD
MACRO
CMCR
No
No
Yes
No
No
Network
Instructions
NETWORK SEND/
NETWORK
RECEIVE
SEND/
RECV
Yes (Can be
used for host
computer via
Host Link con-
nections. Cannot
be used for
Serial Communi-
cations Units or
CPU Unit’s RS-
232C port.)
Yes (Can be
used for host
computer via
Host Link con-
nections. Cannot
be used for
Serial Communi-
cations Units,
CPU Unit’s RS-
232C port, or
Inner Board.)
Yes (Cannot be
used for host
computer via
Host Link con-
nections.)
Yes (Can be
used for host
computer via
Host Link con-
nections.)
Yes (Cannot be
used for host
computer via
Host Link con-
nections.)
DELIVER COM-
MAND
CMND
Yes (Used for
host computer
via Host Link
connections.
Cannot be used
for Serial Com-
munications
Units or CPU
Unit’s RS-232C
port.)
Yes (Used for
host computer
via Host Link
connections.
Cannot be used
for Serial Com-
munications
Units, CPU
Unit’s RS-232C
port, or Inner
Board.)
No
Yes (Can be
used for host
computer via
Host Link con-
nections.)
Yes (Cannot be
used for host
computer via
Host Link con-
nections.)
File Mem-
ory Instruc-
tions
READ DATA FILE/
WRITE DATA FILE
FREAD/
FWRIT
Yes
Yes
No
Yes (FILR/FILW) No
READ PROGRAM
FILE
FILP
No
No
No
Yes
No
CHANGE STEP
PROGRAM
FLSP
No
No
No
Yes
No
Item
Mne-
monic
CJ Series
CS Series
C200HX/HG/HE
CVM1/CV
Series
CQM1H
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...