![Omron CJ1G-CPU series Programming Manual Download Page 342](http://html1.mh-extra.com/html/omron/cj1g-cpu-series/cj1g-cpu-series_programming-manual_742489342.webp)
321
Trial Operation and Debugging
Section 7-2
A message will be displayed on the CX-Programmer or Programming Console
if the limit is exceeded, and further editing will not be possible until the CPU
Unit has completed backing up the data.
Task Size and Cycle Time
Extension
The relation to the size of the task being edited to cycle time extension is as
follows:
When using a version 1 or later CS1 CPU Unit, CS1-H CPU Unit, CJ1 CPU
Unit, or CJ1M CPU Unit, the length of time that the cycle time is extended due
to online editing is almost unaffected by the size of the task (program) being
edited.
When using a pre-EV1 CS1 CPU Unit, the size of the task that is being edited
will determine the length of time that a program will be stopped for online edit-
ing. By splitting the program into smaller tasks, the amount of time that the
cycle is extended will be shorter using the Online Editing function than with
previous PLC models.
Precautions
The cycle time will be longer than normal when a program is overwritten using
Online Editing in MONITOR mode, so make sure that the amount of time that
it is extended will not exceed the cycle monitoring time set in the PLC Setup. If
it does exceed the monitoring time, then a Cycle Time Over error will occur,
and the CPU Unit will stop. Restart the CPU Unit by selecting PROGRAM
mode first before changing to RUN or MONITOR mode.
Note If the task being edited online contains a block program, then previous exe-
cute data such as Standby (WAIT) or Pause status will be cleared by online
editing, and the next execution will be from the beginning.
Online Editing from CX-Programmer
1,2,3...
1.
Display the program section that will be edited.
2.
Select the instructions to be edited.
3.
Select Program, Online Edit, and then Begin.
4.
Edit the instructions.
5.
Select Program, Online Edit, and then Send Changes The instructions
will be check and, if there are no errors, they will be transferred to the CPU
Unit. The instructions in the CPU Unit will be overwritten and cycle time will
be increased at this time.
!Caution
Proceed with Online Editing only after verifying that the extended cycle time
will not affect operation. Input signals may not be input if the cycle time is too
long.
Temporarily Disabling Online Editing
It is possible to disable online editing for a cycle to ensure response charac-
teristics for machine control in that cycle. Online editing from the Program-
ming Device will be disabled for one cycle and any requests for online editing
received during that cycle will be held until the next cycle.
Online editing is disabled by turning ON the Online Editing Disable Bit
(A52709) and setting the Online Editing Disable Bit Validator (A52700 to
A52707) to 5A. When these settings have been made and a request for online
editing is received, online editing will be put on standby and the Online Editing
Wait Flag (A20110) will be turned ON.
When the Online Editing Disable Bit (A52709) is turned OFF, online editing
will be performed, the Online Editing Processing Flag (A20111) will turn ON,
and the Online Editing Wait Flag (A20110) will turn OFF. When online editing
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...