Serial Communications
Section 6-3
RE
EM AREA READ
Reads the contents of the specified number of EM Area words, starting
from the specified word.
WR
CIO AREA WRITE
Writes the specified data (word units only) to the CIO Area, starting
from the specified word.
WL
LINK AREA WRITE
Writes the specified data (word units only) to the Link Area, starting
from the specified word.
WH
HR AREA WRITE
Writes the specified data (word units only) to the Holding Area, starting
from the specified word.
WC
PV WRITE
Writes the PVs (present values) of the specified number of timers/
counters, starting from the specified timer/counter.
WD
DM AREA WRITE
Writes the specified data (word units only) to the DM Area, starting from
the specified word.
WJ
AR AREA WRITE
Writes the specified data (word units only) to the Auxiliary Area, starting
from the specified word.
WE
EM AREA WRITE
Writes the specified data (word units only) to the EM Area, starting from
the specified word.
R#
SV READ 1
Reads the 4-digit BCD constant or word address in the SV of the spec-
ified timer/counter instruction.
R$
SV READ 2
Searches for the specified timer/counter instruction beginning at the
specified program address and reads the 4-digit constant or word
address in the SV.
R%
SV READ 3
Searches for the specified timer/counter instruction beginning at the
specified program address and reads the 4-digit BCD constant or word
address in the SV.
W#
SV CHANGE 1
Changes the 4-digit BCD constant or word address in the SV of the
specified timer/counter instruction.
W$
SV CHANGE 2
Searches for the specified timer/counter instruction beginning at the
specified program address and changes the 4-digit constant or word
address in the SV.
W%
SV CHANGE 3
Searches for the specified timer/counter instruction beginning at the
specified program address and changes the 4-digit constant or word
address in the SV.
MS
STATUS READ
Reads the operating status of the CPU Unit (operating mode, force-set/
reset status, fatal error status).
SC
STATUS CHANGE
Changes the CPU Unit’s operating mode.
MF
ERROR READ
Reads and clears errors in the CPU Unit (non-fatal and fatal).
KS
FORCE SET
Force-sets the specified bit.
KR
FORCE RESET
Force-resets the specified bit.
FK
MULTIPLE FORCE SET/RESET
Force-sets, force-resets, or clears the forced status of the specified
bits.
KC
FORCE SET/RESET CANCEL
Cancels the forced status of all force-set and force-reset bits.
MM
PLC MODEL READ
Reads the model type of the PLC.
TS
TEST
Returns, unaltered, one block of data transmitted from the host com-
puter.
RP
PROGRAM READ
Reads the contents of the CPU Unit’s user program area in machine
language (object code).
WP
PROGRAM WRITE
Writes the machine language (object code) program transmitted from
the host computer into the CPU Unit’s user program area.
MI
I/O TABLE GENERATE
Creates a registered I/O table with the actual I/O table.
QQMR
COMPOUND COMMAND
Registers the desired bits and words in a table.
QQIR
COMPOUND READ
Reads the registered words and bits from I/O memory.
XZ
ABORT (command only)
Aborts the host link command that is currently being processed.
Header
code
Name
Function
Summary of Contents for CJ1G-CPU series
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Conformance to EC Directives 6...
Page 169: ...148 Task Control Instructions Section 3 32...
Page 203: ...182 Programming Device Operations for Tasks Section 4 4...
Page 253: ...232 Using File Memory Section 5 3...
Page 337: ...316 Other Functions Section 6 11...
Page 347: ......
Page 369: ......
Page 373: ......
Page 379: ......
Page 381: ...360 Revision History...