S12 Clock, Reset and Power Management Unit (S12CPMU_UHV_V8)
MC9S12VRP Family Reference Manual Rev. 1.3
112
NXP Semiconductors
Mode. For this COP configuration (ACLK clock source, CSAD set) a latency time (please refer
to CSAD bit description for details) occurs when entering or exiting (Full, Pseudo) Stop Mode.
When bit CSAD is clear the ACLK clock source is on for the COP during Full Stop Mode and
COP is operating.
During Full Stop Mode the RTI counter halts.
After wake-up from Full Stop Mode the Core Clock and Bus Clock are running on PLLCLK
(PLLSEL=1). The COP runs on ACLK and RTI is running on IRCCLK (COPOSCSEL0=0,
RTIOSCSEL=0).
•
Pseudo Stop Mode (PSTP = 1 and OSCE=1)
External oscillator (XOSCLCP) continues to run.
— If COPOSCSEL1=0:
If the respective enable bits are set (PCE=1 and PRE=1) the COP and RTI will continue to run
with a clock derived from the oscillator clock.
The clock configuration bits PLLSEL, COPOSCSEL0, RTIOSCSEL are unchanged.
— If COPOSCSEL1=1:
If the respective enable bit for the RTI is set (PRE=1) the RTI will continue to run with a clock
derived from the oscillator clock.
The clock for the COP is derived from ACLK (trimmable internal RC-Oscillator clock). During
Pseudo Stop Mode the ACLK for the COP can be stopped (COP static) or running (COP active)
depending on the setting of bit CSAD. When bit CSAD is set the ACLK for the COP is stopped
during Pseudo Stop Mode and COP continues to operate after exit from Pseudo Stop Mode.
For this COP configuration (ACLK clock source, CSAD set) a latency time (please refer to
CSAD bit description for details) occurs when entering or exiting (Pseudo, Full) Stop Mode.
When bit CSAD is clear the ACLK clock source is on for the COP during Pseudo Stop Mode
and COP is operating.
The clock configuration bits PLLSEL, COPOSCSEL0, RTIOSCSEL are unchanged.
NOTE
When starting up the external oscillator (either by programming OSCE bit
to 1 or on exit from Full Stop Mode with OSCE bit already 1) the software
must wait for a minimum time equivalent to the startup-time of the external
oscillator t
UPOSC
before entering Pseudo Stop Mode.
4.1.2.4
Freeze Mode (BDM active)
For S12CPMU_UHV_V8 Freeze Mode is the same as Run Mode except for RTI and COP which can be
frozen in Active BDM Mode with the RSBCK bit in the CPMUCOP register. After exiting BDM Mode
RTI and COP will resume its operations starting from this frozen status.
Additionally the COP can be forced to the maximum time-out period in Active BDM Mode. For details
please see also the RSBCK and CR[2:0] bit description field of
Summary of Contents for MC9S12VRP64
Page 16: ...MC9S12VRP Family Reference Manual Rev 1 3 16 NXP Semiconductors ...
Page 46: ...Device Overview S12VRP Series MC9S12VRP Family Reference Manual Rev 1 3 46 NXP Semiconductors ...
Page 236: ...S12S Debug Module S12DBGV2 MC9S12VRP Family Reference Manual Rev 1 3 236 NXP Semiconductors ...
Page 244: ...Interrupt Module S12SINTV1 MC9S12VRP Family Reference Manual Rev 1 3 244 NXP Semiconductors ...
Page 358: ...Timer Module TIM16B2CV3 MC9S12VRP Family Reference Manual Rev 1 3 358 NXP Semiconductors ...
Page 436: ...Supply Voltage Sensor BATSV2 MC9S12VRP Family Reference Manual Rev 1 3 436 NXP Semiconductors ...
Page 528: ...NVM Electrical Parameters MC9S12VRP Family Reference Manual Rev 1 3 528 NXP Semiconductors ...
Page 530: ...Package Information MC9S12VRP Family Reference Manual Rev 1 3 530 NXP Semiconductors ...
Page 531: ...Package Information MC9S12VRP Family Reference Manual Rev 1 3 NXP Semiconductors 531 ...
Page 532: ...Package Information MC9S12VRP Family Reference Manual Rev 1 3 532 NXP Semiconductors ...