5
Menu Key
128
Pulse Laser Station NPL-302 Series Instruction Manual
Specify the azimuth bearing. To do this, enter a value in the AZ or P2 field. P2 is a
second point on the line.
Enter the horizontal distance along the baseline
(Sta), the horizontal distance perpendicular to the
line (O/S), and the vertical distance (dVD).
To calculate the coordinates of the point (PM),
press
[ENT]
in the dVD field. You can change the Z
coordinate here.
A negative value in the Sta field means
the opposite direction along the defined
bearing line.
A negative value in the O/S field is for the
left-hand side of the bearing line.