4
Applications
74
Pulse Laser Station NPL-302 Series Instruction Manual
12.
Select the BS point that you want to use and
press
[ENT]
.
13.
To finish the resection setup, move the cursor
to the BS field and press
[ENT]
.
Advanced feature: Viewing and deleting a measurement in
resection
To check the measurements to each known point,
press the
View
softkey on the calculated STN
(sigma or coordinate) screen.
dHA
Distributed HA errors in each direction
dVD
VD errors between measured distance
and calculated distance
dHD
HD errors between measured distance
and calculated distance
To delete a measurement (because of large sigma
values, for example), highlight the measurement
data or display the detail screen for the measurement. Then press the
DEL
softkey.
The STN coordinates are automatically recalculated.
The minimum data required for a resection is either three angle shots, or one angle
shot and one distance shot. If you use a distance shot, the distance between the
target points must be greater than the measured distance.
Stn-Z is calculated from distance-measured data. If no distances are measured,
then Stn-Z is calculated using angle-only measurements to points with 3D
coordinates.
Summary of Contents for NPL-302 Series
Page 4: ......
Page 5: ...Safety 1 In this chapter Q Introduction Q Laser Safety Q Warnings and Cautions ...
Page 12: ...Safety xii Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 28: ...1 Introduction 8 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 46: ...2 Preparation 26 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 82: ...3 Getting Started 62 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 188: ...5 Menu Key 168 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 196: ...6 Checking and Adjustment 176 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 208: ...8 System Diagrams 188 Pulse Laser Station NPL 302 Series Instruction Manual ...