4
Applications
84
Pulse Laser Station NPL-302 Series Instruction Manual
Specifying the stakeout point by coordinates
40.1
1.
To start a stakeout by coordinates, press
[2]
or
select
XYZ
in the Stakeout menu.
2.
Enter the point name that you want to stake
and press
[ENT]
.
You can also specify the point by code or
radius from the instrument.
If several points are found, they are displayed
in a list. Use
[^]
or
[v]
to move up and down the
list. Use
[<]
or
[>]
to move up or down one page.
3.
Highlight a point in the list and press
[ENT]
.
The delta angle and the distance to the target
are shown.
4.
Rotate the instrument until the dHA is close to
0°00'00". Press
[MSR1]
or
[MSR2]
.
dHA
Difference in horizontal angle to the
target point
HD
Distance to the target point
5.
Ask the rodman to adjust the target position.
When the target is on the intended position,
the displayed errors become 0.000 m (or
0.000 ft).
dHA
Difference in horizontal angle to the
target point
R/L
Right/Left (Lateral error)
IN/OUT
In/Out (Longitudinal error)
CUT/FIL
Cut/Fill
Summary of Contents for NPL-302 Series
Page 4: ......
Page 5: ...Safety 1 In this chapter Q Introduction Q Laser Safety Q Warnings and Cautions ...
Page 12: ...Safety xii Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 28: ...1 Introduction 8 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 46: ...2 Preparation 26 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 82: ...3 Getting Started 62 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 188: ...5 Menu Key 168 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 196: ...6 Checking and Adjustment 176 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 208: ...8 System Diagrams 188 Pulse Laser Station NPL 302 Series Instruction Manual ...