2
Preparation
18
Pulse Laser Station NPL-302 Series Instruction Manual
d.
If the target image does move, rotate the telescope focusing ring. Then repeat
from Step c.
3.
Rotate the tangent screw:
–
The final turn of the tangent screw should be in a
clockwise
directions, to
align the target accurately on the center crosshairs.
Setting the Measurement Mode and Preparing the
Target
2.1
The NPL-362/352/332 has two measurement
modes: Prism mode (
Prism
) and Reflectorless
mode (
N-Prism
). These modes can be changed
at any time by holding down the
[MSR1]
or
[MSR2]
key for one second. For more information, see,
page 60.
Table 2.1 describes how to set the measurement
mode depending on the target you want to measure.
In some cases, you can measure another target that is not appropriate to the set
measurement mode.
Measurement with a prism
21.1
Figure 2.1
Do not
use a prism with scratches, a dirty surface, or a chipped center.
Prisms with thin edges are recommended.
Table 2.1
Measurement modes
Target
Target setting
Prism, reflector sheet
Prism (Prism mode)
Other (reflective materials)
N-Prism (Reflectorless mode)
thin edges
chipped center
thick edges
✓
✕
✕
Summary of Contents for NPL-302 Series
Page 4: ......
Page 5: ...Safety 1 In this chapter Q Introduction Q Laser Safety Q Warnings and Cautions ...
Page 12: ...Safety xii Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 28: ...1 Introduction 8 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 46: ...2 Preparation 26 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 82: ...3 Getting Started 62 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 188: ...5 Menu Key 168 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 196: ...6 Checking and Adjustment 176 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 208: ...8 System Diagrams 188 Pulse Laser Station NPL 302 Series Instruction Manual ...