Applications
4
Pulse Laser Station NPL-302 Series Instruction Manual
107
Two-prism pole
40.1
1.
To enter the two-prism pole function, press
[3]
or select
2Prism Pole
in the Offset menu.
2.
Sight the first prism and press
[MSR1]
or
[MSR2]
.
3.
Sight the second prism and press
[MSR1]
or
[MSR2]
.
4.
Enter the distance between the second prism
and the target point. Alternatively, if you do
not need QA information, you can leave the
distance between the first and the second
prism blank.
5.
If you do enter a P1-P2 distance, the QA
screen appears. Compare the entered value and
the measured distance to check the accuracy of
the observation.
6.
To record the point, press
[ENT]
or the
OK
softkey.
Sample records
SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH
CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020
In this sample data, 0.5090 is the measured value. 0.5060 is the entered value.
Summary of Contents for NPL-302 Series
Page 4: ......
Page 5: ...Safety 1 In this chapter Q Introduction Q Laser Safety Q Warnings and Cautions ...
Page 12: ...Safety xii Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 28: ...1 Introduction 8 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 46: ...2 Preparation 26 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 82: ...3 Getting Started 62 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 188: ...5 Menu Key 168 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 196: ...6 Checking and Adjustment 176 Pulse Laser Station NPL 302 Series Instruction Manual ...
Page 208: ...8 System Diagrams 188 Pulse Laser Station NPL 302 Series Instruction Manual ...