Beta Draft
Configuring date and time
Configuring system administrator settings
3.
Click
Apply
to apply your changes to the running configuration.
Configuring date and time
You set the system date and time in the Configure > Date and Time page.
You can either set the system date and time by entering it manually, or by assigning an NTP server to the AltaVault.
By default, the appliance uses the NetApp-provided NTP server.
To set the date and time manually
1.
Choose Configure > Date and Time.
2.
Complete the configuration as described in this table.
3.
Click
Apply
to apply your changes to the running configuration.
To use Network Time Protocol (NTP) time synchronization
1.
Choose Configure > Date and Time.
2.
Under Date and Time, select Use NTP Time Synchronization.
3.
As a best practice, configure your own internal NTP servers.
Temperature
• Critical Temperature - Enables an alarm and sends an email notification if the CPU temperature
exceeds the rising threshold. When the CPU returns to the reset threshold, the critical alarm is
cleared. The default value for the rising threshold temperature is 80º C; the default reset
threshold temperature is 67º C.
• Warning Temperature - Enables an alarm and sends an email notification if the CPU
temperature approaches the rising threshold. When the CPU returns to the reset threshold, the
warning alarm is cleared.
• Rising Threshold - Specifies the rising threshold. The alarm activates when the temperature
exceeds the rising threshold. The default value is 80º C.
• Reset Threshold - Specifies the reset threshold. The alarm clears when the temperature falls
below the reset threshold. The default is 67º C
.
After the alarm triggers, it cannot trigger again until after the temperature falls below the reset
threshold and then exceeds the rising threshold again.
Upgrade Status
Indicates the status of the upgrade. By default, this alarm is enabled.
Control
Description
Time Zone
Select a time zone from the drop-down list.
If you change the time zone, log messages retain the previous time zone until you reboot
the AltaVault.
Set Time Manually
Change Date - Specify the date in this format: YYYY/MM/DD.
Change Time - Specify military time in this format: HH:MM:SS.
Alarm