![NetApp AltaVault AVA400 Administration Manual Download Page 206](http://html.mh-extra.com/html/netapp/altavault-ava400/altavault-ava400_administration-manual_1669933206.webp)
206
NetApp AltaVault Cloud Integrated Storage Administration Guide
Beta Draft
System maintenance AVA-400, AVA-800
Installing a controller in a chassis
4.
Restart the target AltaVault appliance. After swapping the disks, when you restart the target AltaVault appliance,
the following message displays:
The secure vault fails to unlock. This is because of the serial number mismatch between the appliances.
You cannot use the data store because you cannot access the data store encryption key in the secure vault.
5.
Connect to the target AltaVault appliance through the serial cable.
6.
Log in using the default login admin and password.
7.
At the command line, enter the following CLI commands:
CLI> enable
CLI> configuration terminal
CLI> update controller config
The CLI command,
update controller config
, does the following:
Updates the add-on RAID groups with the new controller configuration.
Clears the secure vault. It is safe to run this CLI command because the information in the secure vault is
already backed up.
Restarts the system.
8.
After AltaVault appliance starts, import the previously-saved configuration into the target AltaVault appliance
using the Import Configuration Wizard.
9.
Reset the Megastore GUID by entering the following CLI commands at the command line:
CLI> enable
CLI> configuration terminal
CLI> megastore guid reset
The last command generates a new megastore GUID based on the serial number of the target AltaVault appliance.
It is important to perform this step before restarting the storage optimization service.
Installing a controller in a chassis
After internal FRU replacement or movement tasks are complete, reinstall the controller module in the system chassis.
Before you begin
Ensure that the chassis enclosure is securely installed in the rack or cabinet.
Ensure the three fan modules associated with the controller module are installed in the system using the steps
described in the procedure,
“Installing fan modules” on page 211
.
To ensure that the system has rebooted correctly, verify that the System attention LED on the chassis front
and the Controller attention LED on the chassis rear are not lit after the system has finished rebooting.
To install a Controller in a Chassis
1.
Align the controller module with the opening in the chassis and then gently push the controller module halfway
into the system.
2.
Re-cable the system: