SNMP traps
linkError
(1.3.6.1.4.1.17163.1.102.4.0.6)
Degraded
An interface on the
appliance has lost its link.
The system has lost one of its Ethernet
links due to a network event. Check the
physical connectivity between the
AltaVault and its neighbor device.
Investigate this alarm as soon as possible.
Depending on what link is down, the
system might no longer be optimizing and
a network outage could occur.
This is often caused by surrounding
devices, like routers or switches
transitioning their interfaces. This alarm
also accompanies service or system restarts
on the AltaVault.
powerSupplyError
(1.3.6.1.4.1.17163.1.102.4.0.7)
Degraded
A power supply on the
appliance has failed (not
supported on all models).
A redundant power supply on the
appliance has failed and needs to be
replaced. Contact NetApp Support for an
RMA replacement soon.
fanError
(1.3.6.1.4.1.17163.1.102.4.0.8)
Degraded
A fan has failed on this
appliance (not supported
on all models).
A fan is failing or has failed and needs to
be replaced. Contact NetApp Support for
an RMA replacement soon.
memoryError
(1.3.6.1.4.1.17163.1.102.4.0.9)
Degraded
A memory error has been
detected on the appliance
(not supported on all
models).
A memory error has been detected. A
system memory stick might be failing. Try
reseating the memory first. If the problem
persists, contact NetApp Support for an
RMA replacement soon.
ipmi
(1.3.6.1.4.1.17163.1.102.4.0.10)
Degraded
An IPMI event has been
detected on the appliance.
Check the details in the
alarm report on the Web
UI (not supported on all
models).
An Intelligent Platform Management
Interface (IPMI) event has been detected.
Check the Alarm Status page for more
detail. You can also view the IPMI events
on the AltaVault by entering the CLI
command:
show hardware error-log all
localFSFull
(1.3.6.1.4.1.17163.1.102.4.0.11)
The appliance local file
system is full.
The AltaVault local file system is full.
Check the Eviction report and contact
NetApp Support.
temperatureCritical
(1.3.6.1.4.1.17163.1.102.4.0.12)
Critical
The system temperature
has reached a critical
stage.
This trap/alarm triggers a critical state on
the appliance. This alarm occurs when the
appliance temperature reaches 90 degrees
Celsius. The temperature value is not user
configurable. Reduce the appliance
temperature.
temperatureWarning
(1.3.6.1.4.1.17163.1.102.4.0.13)
Degraded
The system temperature
has exceeded the
threshold.
The appliance temperature is a
configurable notification. By default, this
notification is set to trigger when the
appliance reached 70 degrees Celsius.
Raise the alarm trigger temperature if it is
normal for the AltaVault to get that hot, or
reduce the temperature of the AltaVault.
scheduledJobError
(1.3.6.1.4.1.17163.1.102.4.0.14)
A scheduled job has
failed during execution.
A scheduled job on the system (for
example, a software upgrade) has failed.
To determine which job failed, use the CLI
or the Management Console.