![NetApp AltaVault AVA400 Administration Manual Download Page 62](http://html.mh-extra.com/html/netapp/altavault-ava400/altavault-ava400_administration-manual_1669933062.webp)
62
NetApp AltaVault Cloud Integrated Storage Administration Guide
Beta Draft
Configuring system administrator settings
Configuring alarm settings
Disk Full
Enables an alarm if the system partitions (not the AltaVault data store) are full or almost full. For
example, AltaVault monitors the available space used to hold logs, statistics, system dumps, and
TCP dumps.
By default, this alarm is enabled.
This alarm monitors the following system partitions:
• /boot Full
• /bootmgr Full
• /config Full
• /tmp Full
• /var Full
Hardware
Fan Error - Enables an alarm when an appliance fan error is detected (the fan is either missing or
running at a low speed).
Battery Backup Unit - Enables an alarm when battery backup unit is detected.
IPMI - Indicates that there has been a physical security intrusion, triggering an Intelligent Platform
Management Interface (IPMI) error. The following events trigger the IPMI alarm:
• Chassis intrusion (physical opening and closing of the appliance case)
• Memory errors (ECC memory errors that can or cannot be corrected)
• Hard drive faults or predictive failures
• Power supply status or predictive failures
The option to reset the alarm appears only after the service triggers the IPMI alarm. To reset the
alarm, click
Clear the IPMI alarm now
.
Memory Error - Enables an alarm when there is a memory error in one or more memory modules.
Unplug the power cords from the power supply and try reseating the memory.
Power Supply - Enables an alarm when an inserted power supply cord does not have power, as
opposed to a power supply slot with no power supply cord inserted. By default, this alarm is
enabled.
RAID - Indicates that the system has encountered RAID errors.
For drive rebuilds, if a drive is removed and then reinserted, the alarm continues to be triggered
until the rebuild is complete.
Important
: Rebuilding a disk drive can take 12 hours or longer.
By default, this alarm is enabled.
You can enable or disable the alarm for a specific RAID disk. To enable or disable an alarm,
choose Settings > Alarms and select or clear the check box next to the RAID disk name. This
alarm monitors and displays the status of the RAID disks.
RAID Integrity Check - Enables an alarm when RAID integrity check is needed.
Shelf Power Supply - Enables an alarm when shelf power supply is needed.
Inconsistent Cloud
Connectivity
Enables an alarm when the connection to the cloud provider is inconsistent.
Inconsistent Cloud Data
Enables an alarm when inconsistency in the data stored in the cloud is detected.
Alarm
Description
Summary of Contents for AltaVault AVA400
Page 2: ...Beta Draft ...
Page 10: ...Beta Draft Contents ...