SNMP traps
AltaVault appliance MIB
memoryErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10009)
A memory error has been
rectified on the appliance.
There was an alarm due to a memory error
on the appliance, but this is now cleared
because the memory error has been
corrected.
ipmiClear
(1.3.6.1.4.1.17163.1.102.4.0.10010)
An IPMI event has been
rectified on the appliance.
An Intelligent Platform Management
Interface (IPMI) event was detected, but it
is now corrected.
localFSFullClear
(1.3.6.1.4.1.17163.1.102.4.0.10011)
The appliance local file
system usage is below
threshold.
The appliance local file system usage
exceeded the permitted threshold, but the
usage is now below the threshold.
temperatureNonCritical
(1.3.6.1.4.1.17163.1.102.4.0.10012)
The system temperature is
no longer in a critical
stage.
The alarm that occurred when the
appliance temperature reached 90 degrees
Celsius is now cleared.
temperatureNormal
(1.3.6.1.4.1.17163.1.102.4.0.10013)
The system temperature is
back within the threshold.
The temperature of the appliance exceeded
the threshold (default value of 70 degrees
Celsius), but is now back within the
threshold.
secureValutUnlocked
(1.3.6.1.4.1.17163.1.102.4.0.10017)
Secure vault is unlocked.
The secure data store can
be used now.
The secure vault, which was locked, is now
unlocked and you can use the secure
datastore.
dirtyCloudClear
(1.3.6.1.4.1.17163.1.102.4.0.10019)
The cloud consistency
issue has been resolved.
Both the cloud bucket and the datastore are
synchronized.
licenseClear
(1.3.6.1.4.1.17163.1.102.4.0.10021)
The appliance is now
properly licensed.
A license on the AltaVault was removed,
had expired, or was invalid, but, the license
has been installed correctly again.
lowSpaceClear
(1.3.6.1.4.1.17163.1.102.4.0.10022)
The appliance now has
enough space for
datastore.
The appliance did not have enough space
for datastore earlier. Now, it has enough
space and the alarm is cleared.
overCapacityClear
(1.3.6.1.4.1.17163.1.102.4.0.10024)
The cloud bucket is no
longer over its licensed
capacity.
The cloud storage meets the storage limit
allocated by its capacity license.
replicationErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10025)
Replication error has been
cleared.
There was an error in the replication
process, but this is now cleared.
replicationPauseClear
(1.3.6.1.4.1.17163.1.102.4.0.10026)
Replication was resumed.
Replication had paused, but it has resumed.
serviceErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10027)
The backup service
initialized properly.
There was an error in the storage
optimization service, but this is now
corrected.
portalUnreachableClear
(1.3.6.1.4.1.17163.1.102.4.0.10028)
The NetApp Cloud Portal
is now reachable.
The AltaVault could not access the NetApp
Cloud Portal, but this is now corrected.
rplctdBytesPendingClear
(1.3.6.1.4.1.17163.1.102.4.0.10029)
Number of bytes pending
replication is within
normal range now.
The number of bytes pending replication
had exceeded the bytes pending alert limit,
but this is now corrected.
cloudDispErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10030)
The appliance is now
connecting to its own
cloud bucket.
The cloud bucket that the AltaVault was
connecting to was in use by another
AltaVault. This issue is now corrected and
the AltaVault is connected to its own cloud
bucket.
Trap and OID
AltaVault
Appliance
State
Text
Description