![NetApp AltaVault AVA400 Administration Manual Download Page 242](http://html.mh-extra.com/html/netapp/altavault-ava400/altavault-ava400_administration-manual_1669933242.webp)
242
NetApp AltaVault Cloud Integrated Storage Administration Guide
AltaVault appliance MIB
SNMP traps
dataIntegrityError
(1.3.6.1.4.1.17163.1.102.4.0.46)
Data integrity check has
reported an inconsistency.
The data integrity check has reported an
inconsistency.
replicationInconsistent
(1.3.6.1.4.1.17163.1.102.4.0.47)
Replication is
experiencing high number
of retries.
The replication is experiencing high
number of retries.
inconsistentCloudData
(1.3.6.1.4.1.17163.1.102.4.0.48)
Possible cloud data
corruption or
inconsistency.
A possible cloud data corruption or
inconsistency has been detected.
softwareUpdateAvailable
(1.3.6.1.4.1.17163.1.102.4.0.49)
Software updated
available.
A software update is available.
firmwareUpgrade
(1.3.6.1.4.1.17163.1.102.4.0.50)
Firmware upgrade
available.
A firmware upgrade is available.
controllerPowerSupplyError
(1.3.6.1.4.1.17163.1.102.4.0.51)
A power supply on the
controller has failed.
A power supply on the controller has
failed.
controllerFanError
(1.3.6.1.4.1.17163.1.102.4.0.52)
A fan has failed on the
controller.
A fan has failed on the controller.
cpuUtilClear
(1.3.6.1.4.1.17163.1.102.4.0.10004)
The average CPU
utilization has fallen back
within the acceptable
threshold.
Average CPU utilization exceeded an
acceptable threshold, but has now fallen
back to an acceptable threshold. If CPU
utilization spikes are frequent, it might be
because the system is undersized.
Sustained CPU load can be symptomatic of
more serious issues. Consult the CPU
Utilization report to gauge how long the
system has been loaded and also monitor
the amount of traffic currently going
through the appliance. A one-time spike in
CPU is normal but NetApp recommends
reporting extended high CPU utilization to
NetApp Support. No other action is
necessary because the alarm clears
automatically.
pagingActivityClear
(1.3.6.1.4.1.17163.1.102.4.0.10005)
Degraded
The system has stopped
paging excessively
(thrashing).
The system that was running low on
memory and was swapping memory pages
to disk has stopped paging excessively, and
the alarm clears.
linkErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10006)
An interface on the
appliance has regained its
link.
The system has regained the Ethernet link
it lost due to a network event and clears the
alarm.
powerSupplyErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10007)
All power supplies are
now functioning
normally.
A redundant power supply had failed on
the appliance, but this is now corrected and
all power supplies are functioning
properly.
fanErrorClear
(1.3.6.1.4.1.17163.1.102.4.0.10008)
All system fans are now
functioning normally.
A fan on the appliance had failed, but now
all fans are functioning normally.