7.5 Cautions for 8-Bit Timer/Event Counters 50 and 51
(1) Timer start error
An error of up to one clock may occur in the time required for a match signal to be generated after timer start.
This is because 8-bit timer counters 50 and 51 (TM50, TM51) are started asynchronously to the count clock.
Figure 7-16. 8-Bit Timer Counter 5n Start Timing
Count clock
TM5n count value
00H
01H
02H
03H
04H
Timer start
Remark
n = 0, 1