7-12 Troubleshooting
Error Notification by BEEP
An error message may not be displayed on the display unit even though the POST detected an error.
In such a case, the beep sounds notifies you an error. The error contents are indicated by the
combination of beep sound patterns. For example, beep sounds once, consecutively three times,
once, and then once (beep code: 1-3-1-1) indicates DRAM refresh test error.
The following table lists the meaning of beep codes and measures against them.
Beep code
Meaning
Action
1-2-2-3
ROM checksum
error
Contact your sales agent to replace the CPU/IO module
motherboard.
1-1-2-4
ROMEXEC code
error
1-3-1-1
DRAM refresh test
error
Check the installation of DIMM board.
If the error persists, contact your sales agent to replace
the DIMM or CPU/IO module motherboard.
1-3-1-3
Keyboard controller
error
Disconnect the keyboard and connect it back on. If the
error persists, request your sales agent to replace the
CPU/IO module motherboard.
1-3-3-1
Failed to detect
memory.
Or, DIMM board
type is incorrect.
1-3-3-2
Initial setting error of
the POST memory
manager
1-3-4-1
RAM address error
1-3-4-3
RAM low byte data
error
1-4-1-1
RAM high byte data
error
Check the installation of DIMM board.
If the error persists, contact your sales agent to replace
the DIMM or CPU/IO module motherboard.
2-2-3-1
Illegal interrupt test
error
2-1-2-3
Copyright check
error
Contact your sales agent.
Failed to initialize
the video BIOS
Failed to initialize
the option ROM
1-2
Failed to expand the
option ROM
Check the motherboard installation if nothing is
displayed on the display unit. If the error persists,
contact your sales agent to replace the CPU/IO module
motherboard.
Check the PCI board installation if the Option ROM of
the added PCI board is not displayed. If the error
persists, contact your sales agent to replace the CPU/IO
module motherboard, PCI module board or added PCI
board with new one.
1-5-1-1
FRB3 monitoring
timeout
Check the installation of CPU. If the error persists,
contact your sales agent.
1-5-2-2
CPU not
implemented error
Check the installation of CPU. If the error persists,
contact your sales agent.
1-5-2-3
CPU configuration
error
Check the installation of CPU. If the error persists,
contact your sales agent.
1-5-4-2
1-5-4-4
Power error
Check the installation of power. If the error persists,
contact your sales agent.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......