4-40 System Configuration
Example
-------------------------------------------------------------------------------------------------
Phoenix ServerBIOS 3 Release 6.0
Copyright 1985-2003 Phoenix Technologies Ltd.
All Rights Reserved
GPJ1. HA. XXXX. X. XXXXXXXXXX
IGPJ BIOS Release X. X
Build Time: XX/XX/XX XX : XX : XX
2x Intel (R) Xeon (R) CPU 3.60GHz
3072M System RAM Passed
2048K Cache SRAM Passed
System BIOS shadowed
Video BIOS shadowed
IPMI Base Board Management Controller was detected.
Device ID : XX Device Revision : XX
IPMI Version : X. X Firmware Revision : XX. XX
Self Test Result : XXXXH
SMBIOS Initialize. . . . . . . . . Passed
System Monitoring Check. Passed
ERROR
8150: NVRAM Cleared By Jumper
Press <F1> to resume, <F2> to Setup
-------------------------------------------------------------------------------------------------
7.
By referring to “Removing CPU/IO Module” on page 8-14, remove the CPU/IO module
#0 from the server.
8.
Restore the previous CMOS clear jumper switch settings. Remove the jumper pins 1-2 of
the CPU/IO module #0 and install them on the jumper pins 7-8.
9.
By referring to “Installing CPU/IO Module” on page 8-16, install the CPU/IO module #0
on the server.
10.
Reconnect the power cord of the CPU/IO module #0 and press the POWER switch to
power on.
11.
After the startup, press the
F2
key during POST to start BIOS SETUP.
12.
Make settings in SETUP as you desire and then the settings by selecting “Exit”
→
“Exit
Saving Changes.” Switch the power off and disconnect the power cord from the outlet.
13.
Clear CMOS for the CPU/IO module #1 by following the steps 3 to 12.
14.
By referring to “Installing CPU/IO Module” on page 8-16, install both CPU/IO modules
on the server.
15.
Connect both power cords.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......