System Configuration 4-43
BMC Configuration Jumper Settings
You can restore the initial values of the BMC configuration information (login name/password etc.),
which are set when you use a remote management function. The values are registered on a CPU/IO
module basis. Because of this, you need restore the values for your target CPU/IO module.
How to restore initial values:
1.
Power off the server and then disconnect the power cords of both CPU/IO modules from the
outlet
2.
Remove your target CPU/IO module from the server by referring to "Removing CPU/IO
Module" on page 8-14.
3.
Make clear settings of the jumper for the BMC configuration of the CPU/IO module.
Remove the CPU/IO module jumper pins (5H) 1-3 and set them to the jumper pins (5H) 1-2
(see page 4-38).
4.
Install the CPU/IO module on the server by referring to “"Installing CPU/IO Module" on
page 8-16.
5.
Connect the power cords of CPU/IO modules and wait for 30 seconds. Then disconnect the
power cords of both CPU/IO modules from outlet again.
6.
Remove your target CPU/IO module from the server by referring to "Removing CPU/IO
Module" on page 8-14.
7.
Restore the original statue of the jumper for the BMC configuration of the CPU/IO module.
Remove the CPU/IO module jumper pins (5H) 1-2 and set them to the jumper pins (5H)
1-3.
8.
Install the CPU/IO module on the server by referring to "Installing CPU/IO Module" on
page 8-16.
IMPORTANT:
By this operation, BMC settings required in NEC DianaScope or remote management functions
for connection with the server will be cleared as well. If you are using NEC DianaScope, store the
settings required to connect to NEC DianaScope in media such as a floppy disk before this
operation, and configure the settings after the operation again. Use NEC DianaScope Agent or
NEC EXPRESSBUILDER system management function to configure and save the BMC settings.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......