7-16 Troubleshooting
Fail to power off the server:
Is the POWER switch enabled?
→
Restart the server and start the BIOS setup utility.
<Menu to check: [Security]
→
[Switch Inhibit]
→
[Enabled]>
POST fails to complete:
Is the DIMM installed?
→
At least one DIMM is required for operation.
Is the memory size large?
→
The memory check may take a time if the memory size is large. Wait for a while.
Did you perform any keyboard or mouse operation immediately after you started the
server?
→
If you perform any keyboard or mouse operation immediately after start-up, POST
may accidentally detect a keyboard controller error and stops proceeding. In such
a case, restart the server once again. Do not perform any keyboard or mouse
operation until the BIOS start-up message appears when you restart the server.
Does the server have appropriate memory boards or PCI card?
→
Operation of the server with unauthorized devices is not guaranteed.
Server reboots while running the SCSI
Select
utility:
Have you modified the Setup settings?
→
From [Server] - [Monitoring Configuration] - [Option ROM Scan Monitoring] of
Setup, select “Disabled.” If [Option ROM Scan Monitoring] is enabled, the
system may reboot while using the SCSI
Select
utility. Change back the setting
after you finish using the utility.
Fail to access to internal or external devices:
Are cables properly connected?
→
Make sure that the interface cables and power cord are properly connected. Also
make sure that the cables are connected in the correct order.
Is that device compliant with NEC Express5800/ft series?
→
Operation of the server with unauthorized devices is not guaranteed.
Is the power-on order correct?
→
When the server has any external devices connected, power on the external
devices first, then the server.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......