![background image](http://html1.mh-extra.com/html/nec/express5800-320fa-l/express5800-320fa-l_user-manual_4267802310.webp)
7-4 Troubleshooting
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive error
TIPS:
For error messages on optional PCI boards, refer to the manual provided with those options.
On-screen error message
Cause
Action
0200 Failure Fixed Disk
•
Hard disk is faulty
•
CPU/IO module is faulty.
•
Replace the hard disk.
•
Replace the CPU/IO module.
0210 Stuck Key
Keyboard connection error
•
Disconnect the keyboard and
connect it back again.
•
Replace the keyboard.
0211 Keyboard error
Keyboard is faulty.
•
Disconnect the keyboard and
connect it back again.
•
Replace the keyboard.
•
If restarting does not help,
replace the CPU/IO module.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
If restarting the server does not
help, replace the CPU/IO module.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked.
Unlock the key switch.
0230 System RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU/IO module..
0231 Shadow RAM Failed at
offset
Shadow RAM is faulty.
•
Replace DIMM.
•
Replace the CPU/IO module..
0232 Extended RAM Failed
at address line
Extended RAM is faulty.
•
Replace DIMM.
•
Replace CPU/IO module.
0233 Memory type mixing
detected
Memory of the different types
is installed.
Memory of the different types is
installed. Replace DIMM with
appropriate one.
0250 System battery is dead
-Replace and run
SETUP
System battery is dead.
•
Replace system battery.
•
Replace CPU/IO module.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......