Installing and Using Utilities 5-61
Start and Stop of Components
To start or stop a component with NEC ESMPRO Manager, use the [Maintenance] tree of the
component in the [ft] tree of the data viewer. Open the tree of the component to be started or
stopped and select the [Maintenance] tree.
To start or stop a component with the Server Maintenance Utility, use the utility screen of the
component.
The table below shows the potential cases in which a component is to be started or stopped.
Start Stop
Compo-
nent
Remote Local Remote
Local
CPU
Module
When the cause of
down is reviewed
and the system is
restarted in module
down state.
Executable in any of
the following module
states (this can be
viewed on manager
screen):
•
Removed
•
Broken
•
Shot
•
Firmware Update
Complete
•
Diagnostics
Passed
When the cause of
down is reviewed
and the system is
restarted in module
down state.
Executable in the
following module
state: (this can be
viewed on Server
Maintenance Utility
screen)
•
Removed
•
Broken
•
Shot
•
Firmware Update
Complete
•
Diagnostics
Passed
When system is
stopped forcibly
due to replacement
or malfunction of
module.
Executable in the
following module
state (this can be
viewed on manager
screen):
•
Duplex
When system is
stopped forcibly
due to replacement
or malfunction of
module.
Executable in the
following module
state: (this can be
viewed on Server
Maintenance Utility
screen)
•
Duplex
IO Module
Same as above
Same as above
Same as above
Same as above
Remote: Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using Server Maintenance Utility
IMPORTANT:
IO modules, SCSI adapters, SCSI buses, and modules under the SCSI enclosure have impact on
each other. You need to be aware of this, for example, when you replace a CPU/IO module. For
details, see “Impact of Module Status Changes” described earlier in this chapter.
When starting modules, ensure to start IO modules first and then CPU modules. To start IO
modules when CPU modules are running and IO modules are stopped, the CPU modules must be
stopped before starting IO modules.
CHECK:
Even if stoppage of a CPU module or IO module is requested, the module will not be stopped if it
is judged that the system would be unable to continue running. It is the same for when the FT
STATUS LED is off.
For example, the module is not stopped when the CPU/IO modules are successfully duplicated,
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......