8-14 System Upgrade
Removing CPU/IO Module
Follow the procedure below to remove the CPU/IO module.
The 320Fa-L model is used in the example quoted here. However steps you should take are the same
for other models.
1.
Stop the CPU/IO module you want to remove.
To this end, use the Server Maintenance Utility of the NEC ESMPRO Agent installed to your
server or the Data Viewer of the NEC ESMPRO Manager.
For the detailed procedure, see "NEC ESMPRO Agent and Manager" - "Maintenance of
NEC Express5800/ft series" in Chapter 5.
NEC ESMPRO Manager
Select [ft] - [CPU Module] - [CPU Module (to be
removed)] - [Maintenance] - [Bring Up/Bring Down]
- [Bring Down].
Server Maintenance Utility
Select [FTServer] - [CPU Module] - [CPU Module (to
be removed)] - [Bring Up/Bring Down] - [Down].
Repeat the operation mentioned above for the IO module and confirm that the status of the
CPU/IO module and the IO module are “Removed.”
2.
If the module POWER LED of the module to be removed is illuminated, press the module
POWER switch to power off the module.
3.
<If you are using the tower model>
Unlock the front door lock with the security key to open the front door.
<If you are using the rack model>
Unlock the front bezel with the security key and detach it.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......