Troubleshooting 7-29
Remote Management Card] from its main menu to write the sensor information
specific to the server to the card.
NEC Express5800/ft series cannot be recognized from management PC:
Did you add the Remote Management Card (option)?
Start NEC EXPRESSBUILDER attached to the device, and select [Tools] –
[Initialize Remote Management Card] from the main menu, and write the
information specific to each server to the card.
Is Java2 Runtime Environment, Standard Edition 1.4.2_04 or later applied to
management PC?
Java2 Runtime Environment, Standard Edition 1.4.2_04 or later is necessary. It
can be installed from the following location.
Start Windows and set NEC EXPRESSBUILDER attached to the device to
CR-ROM on management PC where you want to install. Master control menu is
displayed by Autorun function. Execute JRE installer in NEC DianaScope install
menu from [Software Setup] – [NEC DianaScope].
*Download the latest Java Runtime from the location below:
http://java.sun.com/j2se/
Is the LAN cable properly connected?
→
Make sure that LAN cable is properly connected. The device sensor cannot be
referred unless the cable is properly connected. Check if the cable is connected to the
LAN connector or serial port connector by mistake.
Is the IP address shared?
→
IP address of the management LAN port is set to 192.168.1.1 at the time of shipping.
Change the IP address since it will not be recognized properly if there is same IP
address on the same network.
Is the connection restricted by firewall or gateway?
The connection may be restricted by the setting such as firewall. If directly
connecting the LAN to client PC with cross cable can solve the problem, see
“Network Settings” of “REMOTE MANAGEMENT FUNCTION” in Chapter 4
and check firewall or gateway again.
The device console screen does not appear in web remote KVM console screen:
Is the resolution setting of the device correct?
320Fa-L, 320Fa-LR model
When the device screen is displayed in ft Remote Management Card, change the
screen settings to fit within resolution 1024x768 and refresh rate 75Hz.
320Fa-M, 320Fa-MR model
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...