7-20 Troubleshooting
[Properties] from the displayed menu. When the properties window appears, select
the [Link] tab, and select the item that matches to the connected HUB from the list
box of [Speed and Duplex]. If you click [OK], configuration selected in [Speed and
Duplex] will be effective.
Icon of drive A is changed to that of removal disk:
→
Does not cause any problem.
Machine repeats rebooting at startup:
Is CHKDSK executed at machine startup?
→
Open the utility of the BIOS setup at rebooting and change the following settings:
(Change BIOS settings)
Change [Server] - [Monitoring Configuration] - [Boot Monitoring] to [Disable].
(For details, see page 4-25 “Monitoring Configuration.”)
* After completion of CHKDSK, restart the machine and change the above
setting back to [Enable] and continue the operation.
CHKDSK is executed in the following conditions:
(1) CHKDSK is scheduled to be executed at next system startup
(2) Corruption of file system is detected since the previous startup until
shutdown
(3) Inconsistency (corruption) of file system is detected while mouting at
system startup
Is the value of [Boot Monitoring] in the BIOS setting appropriate?
→
Change the value of [Boot Monitoring] to suit your environment.
(For details, see page 4-25 “Monitoring Configuration.”)
Disk access LEDs on the disks are off:
→
The LEDs may seem to be off when an excessive amount of access causes the
frequent blinking. Check if the LEDs are blinking green when the access is reduced.
CPU/IO module is disconnected:
→
When an error occurred in a CPU/IO module, the following message will be
recorded to the system event log and the CPU/IO module may become disconnected.
In this case, contact your sales agent because device replacement will be required.
Source: HasCtrl
Type: Error
Event ID:
3400
Description: FT nonfatal error occurred on the Module [Module Number].
[Module number] “#0” or “#1.”
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......