5-16 Installing and Using Utilities
Detection of Server Fault
NEC ESMPRO Manager and NEC ESMPRO Agent detect errors causing faults to occur at an early
stage and notify Administrators of fault information real-time.
Early detection of error
If a fault occurs, NEC ESMPRO Agent detects the fault and reports the occurrence of the fault
to NEC ESMPRO Manager (alert report). NEC ESMPRO Manager displays the received alert
in the alert viewer and also changes the status colors of the server and server component in
which the fault occurs. This allows you to identify the fault at a glance. Further, checking the
content of the fault and the countermeasures, you can take appropriate action for the fault as
soon as possible.
Types of reported faults
The table below lists the typical faults reported by NEC ESMPRO Agent.
Component Reported
information
CPU
•
CPU load is over the threshold
•
CPU degrading
Memory
ECC 1-bit error detection, etc.
Power supply
•
Voltage lowering
•
Power failure
Temperature Temperature increase in chassis
Fan
Fan failure (decrease in the number of revolutions)
Storage
File system usage rate
LAN
•
Line fault threshold over
•
Send retry or send abort threshold over
Prevention of Server Fault
NEC ESMPRO Agent includes the preventive maintenance function forecasting the occurrence of a
fault as countermeasures for preventing faults from occurring.
NEC ESMPRO Manager and NEC ESMPRO Agent can set the threshold for each source in the
server. If the value of a source exceeds the threshold, NEC ESMPRO Agent reports the alert to NEC
ESMPRO Manager.
The preventive maintenance function can be set for a variety of monitoring items including chassis
temperature, and CPU usage rate.
Management of Server Operation Status
NEC ESMPRO Agent manages and monitors a variety of components installed in the server. You
can view the information managed and monitored by NEC ESMPRO Agent on the data viewer of
NEC ESMPRO Manager.
NEC ESMPRO Agent also manages and monitors all the components and conditions required to
keep the server reliability at a high level such as hard disks, CPU, memory, fans, power supply, and
temperature.
The following table indicates the functions available on each items of the data viewer.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......