5-26 Installing and Using Utilities
Status of Logical PCI Slots
Because the I/O hub and display controller on a PCI module (IO module) are logical PCI slot
information, PCI module (IO module) are not influenced by them. Therefore, the “Status” of [PCI
slot (ID:0/10/102)] and [PCI slot (ID:0/10/103)] under [PCI module (ID:0/10)] and the “Status” of
[PCI slot (ID:1/11/102)] and [PCI slot(ID:1/11/103)] under [PCI module (ID:1/11)] in the FT tree on
a Data Viewer becomes “Online” and the status color becomes green.
Impact of Module Status Changes
PCI modules (IO modules), SCSI adapters, SCSI buses, and modules under the SCSI enclosure have
impact on each other. For example, when the “Status” item of a module changes to “fault,” it may
be caused by another module’s error. Therefore, you need to check the status of the other modules
based on alert information.
Status Color after Mounting a Hard Disk
When creating a new mirror, the status of the hard disk and its upper component, SCSI enclosure,
will continue to change after you mount a hard disk until the mirror is completed. The OS may take
several minutes to recognize changes of disk status or the disk may need to be rescanned. During
this process, the status color may turn to abnormal, but when the mirror is created successfully, it
will return normal.
LAN Monitoring Report
The LAN monitoring function defines the line status depending on the number of transmission
packets and the number of packet errors within a certain period. Thus, the LAN monitoring function
may report a line fault or high line load only in a temporary high line impedance state. If a normal
state recovery is reported immediately, temporal high line impedance may have occurred thus there
is not any problem.
LAN Monitoring Threshold
Because hardware faults on the network are found in the driver level, NEC ESMPRO Agent does
not monitor line faults. Thus, the value set for "Line fault occurrence rate" of a [LAN] tab of [NEC
ESMPRO Agent properties] in the control panel is not used.
Community Authority
Depending on your OS type or its version, settings for community, SNMP service’s security
function, are not made, or default settings of authority are different
To enable the remote shutdown and threshold change functions via NEC ESMPRO Manager, make
settings of community and set its authority to "READ CREATE" or "READ WRITE."
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......