Troubleshooting 7-31
Event Log
"The NMS Service terminated unexpectedly." is recorded in the system event log:
→
Although the following log may be recorded in the system event log when starting
the system, or after exchanging PCI modules, there is no real problem on
operation. Change of a setup with PROSet II will become invalid if NMS service
stops, but you can change a setup normally because NMS service will be
automatically started when PROSet II is started.
“Source:
Service Control Manager
Event ID:
7031
Description: The NMS service terminated unexpectedly. This has occurred 1
time(s). The following corrective action will be taken in 0
milliseconds: No action.”
iANSMiniport-related logs are recorded in the system event log:
→
The logs of the source “iANSMiniport” are the logs about the duplex of the
network. The following logs may be recorded in the system event log after starting
the system or after setting duplex, but there is no problem on operation.
Source:
iANSMiniport
Type:
Warning
Event ID:
35
Description: Initializing “Virtual Team Adaptor” that lack adapter “Number of
missed adaptors.” Check if all adapters exist and function properly.
Source:
iANSMiniport
Type:
Warning
Event ID:
13
Description: “Physical Adaptor” is invalid in the team.
Source:
iANSMiniport
Type:
Warning
Event ID:
11
Description: The following adapter link is not connected: “Physical Adaptor.”
Source:
iANSMiniport
Type:
Error
Event ID:
16
Description: “Virtual Team Adaptor”: the last adapter lost the link.
The team network lost the connection.
Source:
iANSMiniport
Type:
Warning
Event ID:
22
Description: The primary adapter did not detect the following probe: “Physical
Adaptor.” Reason: The team may be divided.
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......