Troubleshooting 7-33
EventID: 9
Description: The device, \Device\Scsi\adpu320xx, did not respond within the
timeout period.
Source: adpu320
Type: Error
EventID: 117
Description: The driver for device \Device\Scsi\adpu320xx detected a port
timeout due to prolonged inactivity. All associated busses were
reset in an effort to clear the condition.
If this error is recorded many times, the hard disk drive may be faulty. Contact
your service representative.
Event log which warn CPU load monitoring is registered:
→
If NEC ESMPRO Agent cannot get performance information from the OS due to a
temporary resource shortage or high load ratio on the system, it will record the
following event log. However, there is no real problem on operation. (In the
description, Y and X represent alphanumeric characters.)
Source: ESMCpuPerf
Type: Information
Event ID:
9005
Description: Cannot get system performance information now (YYYY
Code=xxxx).
If NEC ESMPRO Agent cannot get information, it will treat the load ratio as 0%.
So, if NEC ESMPRO Agent cannot get information continuously, the CPU load
ratio may appear lower than the actual value.
HAS Fault Tolerance-related logs are recorded in the system event log:
→
The following event logs may be recorded when the server is managed using NEC
ESMPRO Manager, but there is no problem in continue operating the system.
However, there might be a problem in OS or software environment if logs are
recorded repeatedly. Contact your maintenance service company.
Source:
HAS Fault Tolerance
Type:
Warning
Event ID:
204 - 208
Intermittent failure of software which is attributed to the server load may be the
reason for these logs to be recoded.
→
The following event logs may be recorded when operating or
replacement/maintenance of each device of network adapter/SCSI disk/fiber
channel, but there is no problem in continue operating the system. However, there
might be a problem in OS or software environment if logs are recorded regardless
of following the maintenance procedure or they are recorded repeatedly. Contact
your maintenance service company.
Source:
HAS Fault Tolerance
Type:
Warning
Summary of Contents for Express5800/320Fa-L
Page 2: ......
Page 19: ...Precautions for Use 1 3 Rack model Front Rear...
Page 45: ...General Description 2 13 Rack model with the front door open...
Page 48: ...2 16 General Description 27 HCS1 error LED See page 2 29 28 Heat warning LED See page 2 29...
Page 50: ...2 18 General Description Rear View Tower model Rack model...
Page 74: ...2 42 General Description This page is intentionally left blank...
Page 89: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Page 107: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Page 114: ...3 40 Windows Setup and Operation This page is intentionally left blank...
Page 141: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Page 265: ...Installing and Using Utilities 5 65 Sample screen of Server Maintenance Utility...
Page 306: ...6 14 Maintenance This page is intentionally left blank...
Page 400: ...8 44 System Upgrade This page is intentionally left blank...
Page 404: ......
Page 405: ......